6-4-(2)
Serial Interface Menu Operations
Section 6-4
6-4-1
Setting Communications Specifications
Set the same communications specifications in the Controller and the external
device. If the Normal data processing item has been set for a unit, the mea-
surement results will be output in normal (no-protocol) format even if Menu
Operation has been selected for the mode. Xon/Xoff flow control cannot be
used because the codes for the Ctrl + S and Ctrl + Q key inputs are the same
as those for Xon/Xoff.
CHECK
Only a 1:1 connection can be made with menu operations; the Controller’s
menu operations do not support 1:N connections.
RS-232C or RS-422 Connections
1.
Move the cursor to MON or RUN and press the ENT Key.
2.
Select SYS.
The System settings menu will be displayed.
3.
Select Communications.
The communications menu will be displayed.
4.
Select Serial.
---- ---ms
0.Scn 0
MON
Image 0 freeze
SET
MON
RUN
SYS
TOOL
SAVE
System settings
Camera settings
Communication
Display
Operation settings
Measurement control
Startup mode
Date/Time
System information
System settings
Camera settings
Communication
Display
Operation settings
Measurement control
Startup mode
Date/Time
System information
Serial
Normal
Host link
Parallel
Ethernet