6-3-(13)
Host Link Serial Interface
Section 6-3
SeeAlso
Refer to
1RUPDO6HULDO,QWHUIDFH
for details.
CHECK
Sign: Positive (0000) or negative (1111)
1070: Read Unit Data
Reads the parameters and measurement values for the specified unit
The data codes are the same as the ones used for the UNITDATA command.
SeeAlso
Refer to
1RUPDO6HULDO,QWHUIDFH
for details.
CHECK
Write Flags: Each time that data is output, the write flags are switched
between “0000" and “1111". The status of these bits can be monitored to see
when data has been written.
Sign: Positive (0000) or negative (1111)
Read
Area
word
Bits
Contents
15 to 12
11 to 8
7 to 4
3 to 0
+0
0001
0000
0110
0000
Command code
+1
10
3
digit
10
2
digit
10
1
digit
10
0
digit
Unit number (00 to
9999)
+2
10
3
digit
10
2
digit
10
1
digit
10
0
digit
Data code (0 to 9999)
+3
10
3
digit
10
2
digit
10
1
digit
10
0
digit
New setting
+4
Sign
10
6
digit
10
5
digit
10
4
digit
+5
0000
10
-1
digit
10
-2
digit
10
-3
digit
Read
Area
word
Bits
Contents
15 to 12
11 to 8
7 to 4
3 to 0
+0
0001
0000
0111
0000
Command code
+1
10
3
digit
10
2
digit
10
1
digit
10
0
digit
Unit number (00 to
9999)
+2
10
3
digit
10
2
digit
10
1
digit
10
0
digit
Data code (0 to 9999)
Write
Area
word
Bits
Contents
15 to 12
11 to 8
7 to 4
3 to 0
+0
Write
flags
0000
0000
0000
Write flag
+1
10
3
digit
10
2
digit
10
1
digit
10
0
digit
Reading data
+2
Sign
10
6
digit
10
5
digit
10
4
digit
+3
0000
10
-1
digit
10
-2
digit
10
-3
digit