2-13-(12)
Classification
Section 2-13
CHECK
The Controller performs the following 2-stage processing internally.
Interpolation Mode
When 2 or more models are registered to in the same index, set whether or
not to search using an auxiliary model.
The asterisk (*) indicates the default setting.
HELP
Auxiliary model
Auxiliary models are models created between the registered models.
Auxiliary models are automatically created by the Controller when multiple
models have been registered to the same index number.
Note
Indicates the number of models when interpolation mode is set to ON.
Rough Search
Searches all of the measurement
region using a rough search model.
Detailed Search
Measures again using the detailed search model to
compare to the images surrounding the section with
the highest correlation.
Search
Search
Section with the highest
correlation
Rough search model
Detailed search model
Selection
Meaning
ON*
The registered models and auxiliary models will be used in
searches. The measurement will be more stable. Processing time,
however, will be longer.
OFF
The searches will be performed with registered models only.
Number of
registered models
Number of
auxiliary models
Total number of
models (See note.)
2
1
3
3
3
6
4
6
10
5
10
15