2-34-(1)
Trend Monitor
Section 2-34
2-34
Trend Monitor
The Trend Monitor processing item is used to display the measurement results
history on the Monitor. Observation of the measurement value trends helps to
prevent frequent occurrences of non-conforming articles and to find the cause
of NG results when they occur.
400.000
350.000
450.000
Warning
Measurement results over time are shown on a graph.
The latest 1,000 measurement results are held.
Feedback can be provided to earlier processes by setting the warning
range and sounding a warning before too many NG results occur.
Judgement upper limit
Warning range (upper limit)
Warning range (lower limit)
Judgement lower limit