6-2-(8)
Normal Serial Interface
Section 6-2
Normal Communications
Make the settings for flow control and multi-drop connections.
1.
Select Normal communications
The Communications (Normal) window will be displayed.
2.
Set the various communications parameters.
3.
Select End.
The new settings will be registered and the screen in (1.) will return.
The following table shows the possible communications settings. The as-
terisk (*) indicates the default setting.
System settings
Camera settings
Communication
Display
Operation settings
Measurement control
Startup mode
Date/Time
System information
Serial
Normal
Host link
Parallel
Ethernet
Communications(Normal)
Flow control : None
Delimiter : CR
Timeout : [ 5]s
Multi-drop : OFF
Unit No. : [ 1]
End
Item
Possible settings
Flow control
None*
Flow control is not performed.
Use this setting when saving or loading with com-
mands such as SCNLOAD and SCNSAVE.
Xon/Xoff
Flow control is performed by software. Data is trans-
mitted according to the Xon/Xoff codes sent from the
external device.
Delimiter
CR*
Use the same setting that is being used in the per-
sonal computer.
LF
CR + LF
Timeout
Sets the time (in seconds) allowed before a timeout error is gen-
erated.
(1 to 120 s, default setting: 5 s)