7-(8)
Troubleshooting
Section 7-2
Insufficient flash memory.
- Make the region to be registered smaller.
- Delete unnecessary scenes and detection items.
Insufficient model memory.
- Reduce the size of the registered model.
- Delete unnecessary models.
Insufficient work memory.
- Reduce the size of the registered model.
- Delete unnecessary models.
- Reduce the size of regions to be registered.
- Delete unnecessary scenes and units.
Refer to
'HOHWLQJ8QLWVRQSDJH
and
,QLWLDOL]LQJ0HDVXUH
PHQW&RQGLWLRQV&OHDULQJ6FHQHV
.
String must be set within 20 charac-
ters.
Set the character string to within 20 characters.
The “m” and “v” that precede production dates and expiration dates will
not be counted in the number of characters.
E.g., mYY = 2 characters.
Model is not appropriate.
For classification, pattern inspections, and rotation positioning:
- Register an image with high contrast as the model.
- Increase the model size (15
9 pixels min.).
For density defect inspections:
- Reduce the element size or increase the inspection region.
For fine matching:
- Set the model registration range to within 6,6 to 505,477.
For model position compensation:
- Register an image with high contrast as the model.
For circle position compensation:
- Register an image with high contrast as the model.
- The rotation direction reference position will be registered, so use an
image with a defect and register a model.
For ECM searches:
- Adjust the edge extraction level so that the edges of the section to be
registered as the model will be extracted.
- Adjust the edge extraction level so that fine edges appear thicker.
Reason:
No edge-extracted image exists in the region.
Model is too large.
Reduce the size of the region to be registered as the model.
Model is not registered.
Specify the region to be registered as the model.
Label unit isn’t set up.
Set a label unit.
Reason:
The label unit is set to No.
Portion of region is off screen.
Draw the region so that it fits on the screen.
Loaded file error.*
Specify the correct file and reload.
Reason:
- A formatting error may have occurred during data or program file load.
- Data 2MG or greater cannot be loaded using serial communications.
Load the data using the Memory Card.
Refer to
%DFNLQJ8S'DWD
.
Error message
Causes and remedies