2-12-(34)
Detecting Binary Defects
Section 2-12
1.
Select Reference registration.
A cursor will appear at the position of the center of gravity.
2.
To change the position, use the Up/Down and Right/Left Keys to move
the cursor.
3.
Press the ENT Key.
The setting will be registered and the screen in (1.) will return.
STEP 5: Setting the Judgement Conditions
Make settings for the area and center of gravity.
Region0(Area(var.box))
Binary
Measurement conditions
Left edge
Upper edge
Right edge
Lower edge
Reference registration
Judgement conditions
251,184
Reference registration
ENT:Set :Move
Measurement object
Reference position
Judgement conditions
End
Area range (0 to 9,999,999.999)
Range of movement of the measurement object
in the X direction (-9,999.999 to 9,999.999)
Range of movement of the measurement object
in the Y direction (-9,999.999 to 9,999.999)
: Measurement results for the displayed image
Use these values as a reference for setting upper and lower limits.
Range for an OK judgement
Area : 2035.000
[ 0.000 :
247808.000
]
Gravity X : 180.000
[ 0.000 : 511.000]
Gravity Y : 250.000
[ 0.000 : 483.000]