2-34-(16)
Trend Monitor
Section 2-34
2-34-6
Referencing NG Results
The NG measurement values and time the NG results were generated can be
browsed from the measurement results recorded on the Trend Monitor. Up to
the latest 35 NG results can be browsed.
This NG referencing function is useful for analyzing the cause of NG results by
giving a grasp of the time frame in which the NG results occurred.
CHECK
To View the Trend Monitor NG Image
Set the conditions as described below to save measurement images on the
Trend Monitor only when NG results are returned.
• Set System/Measurement control/Save image to NG only.
• Set all units other than Trend Monitor unit to OK.
Press the SHIFT+Up/Down Keys on the Measurement Screen to display the
desired NG image and then go to NG display on the Trend Monitor and switch
to the NG result for that NG image.
1.
Select NG display.
The graph will be displayed.
Disp.200
NG display
Last 35 NG Meas.: 126.000
Time : 13:25:35
400.000
350.000
450.000
A number of past NG results are
displayed.
Measurement value and time NG
result occurred.
Number of past NG results
3.Trend monitor
Measurement
Judgement conditions
Display range
Detailed conditions
NG display
Save data
Disp.200
NG display
Last 35 NG Meas.: 126.000
Time : 13:25:35
400.000
350.000
450.000