6-2-(53)
Normal Serial Interface
Section 6-2
Note
If these settings are changed, one rectangular region will be set and any previ-
ously drawn figures will be deleted. This is true for regions 1 to 7 as well.
CHECK
Only the allocations for region 0 are listed here. Refer to the allocations for
region 0 to calculate the numbers for regions 1 to 7.
Classification (Measurement Data)
The following settings data is for processing item region and reference position mea-
surement.
164
Region 0
Region upper left X (0 to 511) (See note.)
165
Region upper left Y (0 to 483) (See note.)
166
Region lower right X (0 to 511) (See note.)
167
Region lower right Y (0 to483) (See note.)
168
Region upper left X (left edge) (0 to 511)
169
Region upper left Y (left edge) (0 to 483)
170
Region lower right X (left edge) (0 to 511)
171
Region lower right Y (left edge) (0 to483)
172
Region upper left X (upper edge) (0 to 511)
173
Region upper left Y (upper edge) (0 to 483)
174
Region lower right X (upper edge) (0 to 511)
175
Region lower right Y (upper edge) (0 to483)
176
Region upper left X (right edge) (0 to 511)
177
Region upper left Y (right edge) (0 to 483)
178
Region lower right X (right edge) (0 to 511)
179
Region lower right Y (right edge) (0 to483)
180
Region upper left X (lower edge) (0 to 511)
181
Region upper left Y (lower edge) (0 to 483)
182
Region lower right X (lower edge) (0 to 511)
183
Region lower right Y (lower edge) (0 to483)
184
Reference position X (0 to 511)
185
Reference position Y (0 to 483)
186
Region 1
Binary level upper limit (0 to 255)
to
... (Same as for region 0)
552
Region 7
Binary level upper limit (0 to 255)
to
... (Same as for region 0)
611
Reference position X (0 to 511)
612
Reference position Y (0 to 483)
Data
Details
Data
Details
Measure-
ment
data
0
Judgement result
-2: Not measured.
-1: NG
0: OK
1
Measurement position X
2
Measurement position Y
3
Correlation
4
Index number