2-25-(15)
Labeling
Section 2-25
2-25-8
Measurement Screens
Detailed measurement values can be displayed on the screen in Monitor and
Run modes. These values are useful when adjusting measurement conditions.
This section describes what kind of information can be displayed for labeling.
SeeAlso
Refer to
6(&7,210RQLWRU0RGHDQG5XQ0RGH
for details on Monitor and
Run modes.
CHECK
Press the SHIFT+ESC Keys on the Run Screen to access the following screen
and change Display results to Details.
Use the Up or Down Key to change to the unit for which labeling is set and the
following detailed screens will be displayed.
End
Image 0 Freeze
Image status
Freeze(Before scroll)
Display image
Image size
Display results
0.Scn 0
RUN
:
:Image0
: All
:
Details
NG
67ms
OK 45ms
1. Labeling
Judge : OK
Number of Labels : 3
Area : 135
Gravity X : 150.212
Gravity Y : 250.533
0.Scn 0
RUN
The measurement region is displayed
in the OK color for an OK judgement;
in the NG color for an NG judgement.
Judgement result for this Unit
Display is inverted for NG.
A circle is displayed at the center
of gravity for an OK judgement; an
ex, for a NG judgement.