6-2-(35)
Normal Serial Interface
Section 6-2
The following settings data is for gravity and area and gravity and axis measurement.
Settings
data
32
Region 0
Binary level upper limit (0 to 255)
33
Binary level lower limit (0 to 255)
34
Reverse binary level
0: Not reversed
1: Reversed
35
X upper limit (-9,999.999 to 9,999.999)
36
X lower limit (-9,999.999 to 9,999.999)
37
Y upper limit (-9,999.999 to 9,999.999)
38
Y lower limit (-9,999.999 to 9,999.999)
39
Area upper limit (0.000 to 9,999,999.999)
40
Area lower limit (0.000 to 9,999,999.999)
41
Skipping X (1 to 15)
42
Skipping Y (1 to 15)
The following settings data is for gravity and area measurement.
43
Region 0
Fill profile
0: OFF
1: ON
The following settings data is for gravity and axis measurement.
44
Region 0
Axis angle upper limit (-180.000 to 180.000)
45
Axis angle lower limit (-180.000 to 180.000)
The following settings data is for processing item region and reference position mea-
surement.
Settings
data
46
Region 0
Region upper left X (0 to 511) (See note 2.)
47
Region upper left Y (0 to 483) (See note 2.)
48
Region lower right X (0 to 511) (See note 2.)
49
Region lower right Y (0 to483) (See note 2.)
50
Reference position X (0 to 511)
51
Reference position Y (0 to 483)
The following settings data is for gravity and area and gravity and axis measurement.
Settings
data
52
Region 1
Binary level upper limit (0 to 255)
53
Binary level lower limit (0 to 255)
54
Reverse binary level
0: Not reversed
1: Reversed
55
X upper limit (-9,999.999 to 9,999.999)
56
X lower limit (-9,999.999 to 9,999.999)
57
Y upper limit (-9,999.999 to 9,999.999)
58
Y lower limit (-9,999.999 to 9,999.999)
59
Area upper limit (0.000 to 9,999,999.999)
60
Area lower limit (0.000 to 9,999,999.999)
61
Skipping X (1 to 15)
62
Skipping Y (1 to 15)
The following settings data is for gravity and area measurement.
63
Region 1
Fill profile
0: OFF
1: ON
Data