6-2-(13)
Normal Serial Interface
Section 6-2
6-2-2-1
CLRMEAS: Clear Measure
Function
Clears the measurement values for the current scene.
Input
CLRMEAS Delimiter
Output
Command executed correctly:
OK Delimiter
Command not executed correctly:
ER Delimiter
6-2-2-2
DATASAVE
Function
Saves the current scene group data and system data. (Data for scene group 0
is saved to flash memory, data for scene groups 1 to 31 is saved to the Mem-
ory Card, and the system data is saved to the Memory Card.)
Input
DATASAVE Delimiter
Output
Command executed correctly:
OK Delimiter
Command not executed correctly:
ER Delimiter
Precaution
Do not turn OFF the Controller’s power supply until a response has been
received.
6-2-2-3
DATE
Function 1
Reads the current date and time.
Input
DATE Delimiter
Output
Command executed correctly:
Month Day Hour Minute Year. Second Delimiter
OK Delimiter
Command not executed correctly:
ER Delimiter
Example
This example returns the time and date at 12:30:00 on August, 30 2000.
Input
DATE Delimiter
Output 083012302000.00 Delimiter
OK Delimiter