background image

Binh Duong Province, VIETNAM

Manufacturer

EU-representative

Production facility

438A Alexandra Road, #05-05/08

Alexandra Technopark, Singapore 119967

www.omronhealthcare-ap.com

Asia Pacific HQ

OMRON HEALTHCARE EUROPE B.V.

Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS

OMRON HEALTHCARE Co., Ltd.

53, Kunotsubo, Terado-cho, Muko, KYOTO,

617-0002 JAPAN

OMRON HEALTHCARE SINGAPORE PTE LTD.

14G1648

3262572-4B

Automatic Blood Pressure Monitor

Model HEM-7280T

Instruction Manual

Package includes:

HEM-7280T-AP_B_M03_151013.pdf

Automatic Blood Pressure Monitor

Model HEM-7280T

Instruction 

Manual

Summary of Contents for HEM-7280T

Page 1: ...Q OMRON HEALTHCARE EUROPE B V Scorpius 33 2132 LR Hoofddorp THE NETHERLANDS OMRON HEALTHCARE Co Ltd 53 Kunotsubo Terado cho Muko KYOTO 617 0002 JAPAN OMRON HEALTHCARE SINGAPORE PTE LTD 14G1648 3262572 4B Automatic Blood Pressure Monitor Model HEM 7280T Instruction Manual Package includes HEM 7280T AP_B_M03_151013 pdf Automatic Blood Pressure Monitor Model HEM 7280 T Instructio n Manual ...

Page 2: ... using the device on the arm with an arterio venous A V shunt Do not use the device with other medical electrical ME equipment simultaneously Do not use the device in the area of HF surgical equipment MRI or CT scanner or in an oxygen rich environment The air tube or the AC adapter cable may cause accidental strangulation in infants Contains small parts that may cause a choking hazard if swallowed...

Page 3: ...ment results Do not use a mobile phone or other devices that emit electromagnetic fields near the device except when in use for wireless communications This may result in incorrect operation of the device Do not disassemble the monitor or arm cuff This may cause an inaccurate reading Do not use in a location with moisture or a location where water may splash on the device This may damage the devic...

Page 4: ...tions Do not forcibly crease the arm cuff or the air tube excessively Do not press the air tube while taking a measurement To unplug the air plug pull on the air plug at the connection with the monitor not the tube itself Do not drop the monitor or subject device to strong shocks or vibrations Do not inflate the arm cuff when it is not wrapped around your arm Do not use the device outside the spec...

Page 5: ...tolic blood pressure Diastolic blood pressure Battery symbol low depleted Cuff wrap guide symbol Heartbeat symbol Flashes during measurement Date Time display Morning average symbol Evening average symbol Morning hypertension symbol Irregular heartbeat symbol SYNC symbol Connection symbol OK symbol Deflation symbol Pulse display Memory number Open the rear cover page to read the following The lett...

Page 6: ...ults we recommend you consult your physician Follow the directions of your physician Average Value Symbol The average value symbol is displayed when you press and hold the Memory button for more than 3 seconds The most recent average value appears on the display screen Cuff Wrap Guide Symbol If the cuff was wrapped too loosely it may cause unreliable results If the wrapping of cuff is too loose th...

Page 7: ...r at least 5 minutes before taking the measurement 2 Stress raises blood pressure Avoid taking measurements during stressful times 3 Measurements should be taken in a quiet place 4 Remove tight fitting clothing from your arm 5 Sit on a chair with your legs uncrossed and your feet flat on the floor Rest your arm on a table so that the arm cuff is at the same level as your heart 6 Remain still and d...

Page 8: ...he display turn the monitor off and remove all the batteries Replace with 4 new batteries at the same time Long life alkaline batteries are recommended The measurement values continue to be stored in memory even after the batteries are replaced The supplied batteries may have a shorter life Dispose of the device components and optional accessories according to applicable local regulations Unlawful...

Page 9: ...ctions 1 Download and install the free OMRON connect app on your smartphone If you already have the OMRON connect app go to Menu Device Add Device 2 Open the app on your smartphone and follow set up and pairing instructions List of Compatible Smartphones at www omronconnect com devices For details visit www omronconnect com HEM 7280T AP_B_M fm Page 8 Tuesday October 13 2015 2 51 PM ...

Page 10: ...ection symbol and the P flashes on the device s display 4 Open the app on your smartphone and follow the device pairing instructions shown on your smartphone while the connection symbol is flashing on the device s display HEM 7280T AP_B_M fm Page 9 Tuesday October 13 2015 2 51 PM ...

Page 11: ...y sync with the device when paired When Err appears refer to Connection failure in section 4 2 for more detail Notes You can pair up to 4 destination smartphones with the monitor When paired with 5 or more smartphones any information previously stored in your device will be overwritten Any readings currently saved in the blood pressure monitor s memory will automatically be transferred to the app ...

Page 12: ...e s display You can pair this device with your smartphone and refer to Pairing this Device with a Smartphone page 8 2 Then press the connection button again The year flashes on the Date Time display 3 Push or button to change the year Push button to confirm the year and then the month flashes Repeat the same steps to change the month day hour and minute 4 Press the START STOP button to turn the mo...

Page 13: ...Notes When you take a measurement on the right arm the air tube will be at the side of your elbow Be careful not to rest your arm on the air tube The blood pressure can differ between the right arm and the left arm and the measured blood pressure values can be different OMRON recommends to always use the same arm for measurement If the values between both arms differ substantially please check wit...

Page 14: ...lcohol or caffeine smoking exercising or eating 30 minutes before taking a measurement Sit on a chair with your legs uncrossed and your feet flat on the floor Sit upright with your back straight Sit with your back and arm being supported The arm cuff should be placed on your arm at the same level as your heart c d HEM 7280T AP_B_M fm Page 13 Tuesday October 13 2015 2 51 PM ...

Page 15: ... 2 people using USER ID 1 and USER ID 2 1 Select your USER ID 1 or 2 Push the switch up or down to select USER ID 2 Press the START STOP button The arm cuff starts to inflate automatically START INFLATE DEFLATE COMPLETE Cuff Wrap Guide Symbol If your systolic pressure is more than 210 mmHg After the arm cuff starts to inflate press and hold the START STOP button until the monitor inflates 30 to 40...

Page 16: ...r the measurement is complete you can transfer the data measurement results of blood pressure and pulse rate Notes The stored data can be transferred all at once The date and time settings of your smartphone will sync with the device when transferred Sync occurs if the time between smartphone and device differs more than 10 minutes 1 Open the app on your smartphone 2 Pull down to refresh the scree...

Page 17: ... measurement data is transferred successfully If the display on the right is shown the data is transferred successfully When Err appears refer to Data cannot be sent in section 4 2 for more detail HEM 7280T AP_B_M fm Page 16 Tuesday October 13 2015 2 51 PM ...

Page 18: ...late automatically DO NOT adjust medication based on measurement results from this blood pressure monitor Take medication as prescribed by your physician Only a physician is qualified to diagnose and treat High Blood Pressure This monitor is not intended to be a diagnostic device Always consult your physician Self diagnosis of measurement results and self treatment are dangerous Read If your systo...

Page 19: ...en the SYNC symbol appears on the display transfer the data before the measurement values are deleted Refer to To Transfer the Data page 15 When viewing the measurement value taken without setting the date and time is displayed instead of the date and time To View the Measurement Values Stored in Memory 1 Select your USER ID 1 or 2 2 Press the button The Memory number appears for a second before t...

Page 20: ...erage value is not calculated If there are no measurement values stored in the memory the screen to the right is displayed To View the Weekly Average Value The monitor calculates and displays weekly averages for the measurements taken in the morning and evening within 8 weeks for each user Note The week begins Sunday at 2 00 1 Select your USER ID 1 or 2 HEM 7280T AP_B_M fm Page 19 Tuesday October ...

Page 21: ...ars on the display Press the or button to display the previous weeks Note If there are no measurement values stored in the memory the screen to the right is displayed This week Morning average Last week Morning average 7 weeks ago Morning average Continue to press This week Evening average Last week Evening average 7 weeks ago Evening average 2 weeks ago Morning average 2 weeks ago Evening average...

Page 22: ...e measurements taken within 10 minutes of the last measurement of the evening First measurement of the morning Within 10 minutes 11 59 4 00 Measurements of the morning Up to 3 measurements Morning Blood Pressure Measurement Measurement Measurement Measurement Measurement Measurement Sunday Monday Tuesday Wednesday Thursday Friday Saturday Measurements of the evening Last measurement of the evening...

Page 23: ... USER ID 1 or 2 2 Press the Memory button while the memory symbol appears 3 While holding the button down press the START STOP button for more than 3 seconds Note You cannot partially delete the values stored in the memory All values for the user you select will be deleted HEM 7280T AP_B_M fm Page 22 Tuesday October 13 2015 2 51 PM ...

Page 24: ...r has been off before starting the instructions below 1 Press and hold the connection button for more than 10 seconds 2 Release the button when OFF appears on the display 3 Press the START STOP button to turn the monitor off Note The monitor will automatically turn off after 2 minutes On aircraft In hospitals While abroad HEM 7280T AP_B_M fm Page 23 Tuesday October 13 2015 2 51 PM ...

Page 25: ...nstructions below 1 Press and hold the connection button for more than 10 seconds 2 Release the button when ON appears on the display 3 Press the START STOP button to turn the monitor off Note The monitor will automatically turn off after 2 minutes HEM 7280T AP_B_M fm Page 24 Tuesday October 13 2015 2 51 PM ...

Page 26: ...se the and START STOP button when CLr appears on the display The CLr will appear on the display when your monitor has been initial setting 3 Press the START STOP button to turn the monitor off The monitor will automatically turn off after 10 seconds even forgetting the off the monitor Notes Initial setting of the monitor will not delete the information in the app The monitor will automatically tur...

Page 27: ... contact your physician Arm cuff is applied too loosely Apply the arm cuff tighter Refer to section 3 1 The batteries are low Recommend to replace the batteries with new ones ahead of time Refer to section 2 1 The batteries are depleted Replace 4 batteries with new ones at once Refer to section 2 1 Communication failed Refer to section 4 2 Device error Contact your local OMRON representative HEM 7...

Page 28: ...y inflate the arm cuff manually until it is 30 to 40 mmHg above your previous measurement result Refer to section 3 3 The arm cuff was inflated exceeding the maximum allowable pressure and then deflated automatically Do not touch the arm cuff and or bend the air tube while taking a measurement Do not inflate the arm cuff more than necessary Refer to section 3 3 Movement during measurement Repeat m...

Page 29: ...es not rise The air connector is not securely connected into the air jack Make sure that the air tube is connected securely Refer to section 3 1 Air is leaking from the arm cuff Replace the arm cuff with a new one Refer to Chapter 6 Arm cuff deflates too soon The arm cuff is loose Apply the arm cuff correctly so that it is firmly wrapped around the arm Refer to section 3 1 Cannot measure or readin...

Page 30: ...tphone is turned off Turn on the Bluetooth feature of the smartphone and your monitor and try sending the data again The Bluetooth feature of the blood pressure monitor is turned off Refer to To turn ON the Bluetooth in 3 Using the Device The blood pressure monitor did not pair successfully to the smartphone Try to pair the devices again Refer to Pairing this Device with a Smartphone in section 2 ...

Page 31: ...r problems Press the START STOP button and repeat measurement Replace the batteries with new ones If the problem continues contact your local OMRON representative Problem Cause Solution HEM 7280T AP_B_M fm Page 30 Tuesday October 13 2015 2 51 PM ...

Page 32: ...ned cloth and neutral soap to clean on the monitor and the arm cuff Changes or modification not approved by the manufacturer will void the user warranty Do not disassemble or attempt to repair the device or components Consult your local OMRON representative Calibration and Service The accuracy of this device has been carefully tested and is designed for a long service life It is generally recommen...

Page 33: ...crease the air tube excessively 3 Place the monitor and the arm cuff in the storage case Do not store the device in the following situations If the device is wet Locations exposed to extreme temperatures humidity direct sunlight dust or corrosive vapours such as bleach Locations exposed to vibrations shocks or where it will be at an angle HEM 7280T AP_B_M fm Page 32 Tuesday October 13 2015 2 51 PM...

Page 34: ...the AC adapter plug into the AC adapter jack on the rear side of the monitor 2 Plug the AC adapter into an electrical outlet To disconnect the AC adapter unplug the AC adapter from the electrical outlet first and then remove the AC adapter plug from the monitor Arm Cuff AC adapter Arm circumference 17 22 cm Arm circumference 22 42 cm Small Cuff HEM CS24 Wide Range Soft Cuff HEM RML31 Adapter S Mod...

Page 35: ...atteries operating temperature and humidity 23 C 65 RH cuff circumference 25 cm max pressure170 mmHg Applied part Protection against electric shock Internally powered ME equipment When using only the batteries Class II ME equipment Optional AC adapter Operating temperature humidity air pressure 10 C to 40 C 15 to 85 RH 700 to 1060 hPa Storage temperature humidity air pressure 20 C to 60 C 10 to 95...

Page 36: ...RON devices which is the Pressure Sensor is produced in Japan This Product operates in the unlicensed ISM band at 2 4 GHz In case this Product is used around the other wireless devices including microwave and wireless LAN which operate same frequency band of this Product there is a possibility that interference occurs between this Product and such other devices If such interference occurs please s...

Page 37: ...his from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions o...

Page 38: ...pical symptoms are skipped heartbeats premature contraction an abnormally rapid tachycardia or slow bradycardia pulse Why is it a Good Thing to measure Blood Pressure at Home Many factors such as physical activity anxiety or the time of day can influence your blood pressure A single measurement may not be sufficient for an accurate diagnosis Thus it is best to try and measure your blood pressure a...

Page 39: ...38 HEM 7280T AP_B_M fm Page 38 Tuesday October 13 2015 2 51 PM ...

Page 40: ...39 HEM 7280T AP_B_M fm Page 39 Tuesday October 13 2015 2 51 PM ...

Page 41: ...40 HEM 7280T AP_B_M fm Page 40 Tuesday October 13 2015 2 51 PM ...

Page 42: ...s during measurement and gives a warning signal with the measurement result Important Safety Information 1 1 Know Your Device 4 2 Preparation 7 2 1 Battery Installation 7 2 2 Pairing this Device with a Smartphone 8 4 Error Messages and Troubleshooting 26 4 1 Error Messages 26 4 2 Troubleshooting 28 5 Maintenance and Storage 31 5 1 Maintenance 31 5 2 Storage 32 7 Technical Data 34 8 Some Useful Inf...

Reviews: