background image

MASS FLOW MONITOR

MODEL

TF0

□□-

P

A G

 

A

Every  OVAL 

Mass  Flow  Monitor 

is  fabricated  and  shipped  from  our  factory  under  stringent  quality 

control. 

In order to maintain its design performance throughout its life, this manual offers the operator the necessary 
installation, operation and maintenance information. 

Be well familiar with these instructions before you place the product in service and keep this manual at the 
field location for ready reference.

Ins. No.

 S-193-11-E

TF0

PG

A

TF00

PG

A

TF0

AG

A

TF00

AG

A

TF00

AG

A

Summary of Contents for TF1015-P11G-11 A Series

Page 1: ...its design performance throughout its life this manual offers the operator the necessary installation operation and maintenance information Be well familiar with these instructions before you place t...

Page 2: ...ariables Parameter Display 3 Default Parameter Settings Parameter Recon guration 9 Alarm Features 0 Dummy Pulse Output Analog Output Trim Analog Trim mA Analog Trim 0mA Error Messages 9 GENERAL SPECIF...

Page 3: ...ed to the installation site in the shipping container used for transit from the factory During transportation exercise care to avoid impact shock and rainwater 1 3 Storage Considerations Storing your...

Page 4: ...t temperature differential As the flowing process fluid mass flow dissipates heat from the latter which serves as a heater its supply power increases in order to maintain the temperature differential...

Page 5: ...resistive resistance elements changes to maintain the heat resis tance at a constant level approx 30 C Transmitter Changes in supply power voltage and current are transformed into a owrate signal whic...

Page 6: ...al Orientation There is no restriction on physical orientation of the monitor to cause loss of the accuracy Make sure that the actual ow direction conforms to the ow direction arrow indicated on the m...

Page 7: ...n Install the removed spacers over the bosses Place the display board in line with the top panel and secure it with four screws 2 6 8 with tightening torque 45cN m Align the opening in the top panel w...

Page 8: ...tion and orientation Torque speci cation 0 3 cN m Elbow Fig 30 min Monitor body Straight tube D Meter I D CAUTION With metal tubes tubing stresses could damage the flowmeter at its metal fittings Do n...

Page 9: ...00 300 200 100 0 0 0 1 0 2 0 3 0 4 0 5 06 0 7 0 04 Line pressure MPa Max service flowrate L min normal Nominal size 20 mm Nominal size 15 mm Line pressure vs maximum service owrate nominal sizes mm an...

Page 10: ...Transmission cable Depends on your speci cation The following cables are supplied depending on the th digit of the product code conductor shielded cable of 3 meters long O D 3mm Fixed to this unit con...

Page 11: ...l 1 3 4 2 WHT Flow analog output BLK Alarm 1 output BLU COM power max 30VDC 20mADC 24VDC 10 Cable OMRON Cable OVAL Model XS2F D42 80 F Note For cables refer to the following figures When product code...

Page 12: ...r max 30VDC 20mADC 24VDC 10 Model XS2F D42 80 F 25 cm 3m 1 SUP power 4 Alarm 1 output 3 COM power 2 Flow analog output Cable OMRON Cable OVAL Note For cables refer to the following figures When produc...

Page 13: ...mADC max 30VDC 20mADC 24VDC 10 Model XS2F D42 80 F 25 cm 3m 1 SUP power 4 Alarm 1 output 3 COM power 2 Flow analog output Cable OMRON Cable OVAL Note For cables refer to the following figures When pro...

Page 14: ...or shield cable Length 3 m O D 3 mm Directly coupled to the product body 2 Connector via interconnect cable with cable OVAL cable conductor shield cablewith connector Length 3 m O D mm Packed together...

Page 15: ...the hourly instant owrate Reads in L min normal Resettable total ow Indicates the total ow that has own since the last RESET op eration Pressing the RESET button while total reset ow is displayed set...

Page 16: ...ysteresis Alarm hysteresis If owrate uctuation is excessive causing frequent alarm ON OFF trips select a larger value Setpoint reads in L min normal Alarm status Alarm I status setpoint By selecting e...

Page 17: ...s owrate reads 0 Reads in L min normal Dummy output A 0Hz pulse output is available irrespective of the owrate curently in measurement You can use this feature in verifying the connections with other...

Page 18: ...full scale L min normal 0 to 99999 00 00 00 000 000 Analog Damping sec 0 to 99 0 0 0 0 0 Backlight setting On EC OF SL On On On On On 8 3 Default Parameter Settings Parameters are set to the followin...

Page 19: ...blink Pressing the MODE button moves the blinking digit one place to the left in the hundreds place blinks Press the RESET button 9 times to adjust the gure to Pressing the RESET button increases the...

Page 20: ...iven for individual parameters Alarm setpoint Set the owrate L min normal to be at the upper alarm Alarm hysteresis Alarm is cancelled when the following conditions are met Select the appropriate alar...

Page 21: ...e the opposite states shown in the above gure Setup example where alarm hysteresis exists and alarm immunity time is set to 0 Alarm conditions Instant owrate Alarm setpoint Alarm cancel conditions Ins...

Page 22: ...limit in the alarm immunity range this monitor can prevent the alarm from being activated in a situation like this While the following condition continues the low alarm remains inoperative Flowrate Lo...

Page 23: ...hin alarm immunity time Beyond alarm immunity time Alarm 1 hysteresis NOTES When alarm status lower digit is set to o the ON and OFF of alarm output become the opposite states shown in the above gure...

Page 24: ...un dummy pulse output Description Dummy pulse output window Hold the MODE button depressed for sec to bring up the dummy pulse out put standby mode The display reads as shown at left At this point pul...

Page 25: ...value the analog output ammeter reads For example if the ammeter reads 3 990 set a value 3 990 The figure place of interest blinking digit moves to the left each time MODE switch is turned on The blin...

Page 26: ...urned on The blinking gure increases by one each time the RESET switch is turned on Holding the MODE button depressed for seconds the numerical value becomes a blinking 0 00 and the transmitter produc...

Page 27: ...More than of analog full scale value is owing due to excessive owrate or the like Take the following countermeasures Lower the owrate Increase the set value of analog full scale value parameter Settin...

Page 28: ...n collector output Pulse width adjustable from to 0 msec Alarm points open collector output Flowrate analog to 0mA Max load resistance 00 Alarm independent set points can be chosen settings hysteresis...

Page 29: ...t x 3 Flow pulse two alarm points Output x 3 Flow pulse ow analog single alarm point Version A Standard Output terminals Nom size mm 0 0 0 1 Direct coupled cable output x 3 conductor 3 meters long 2 C...

Page 30: ...ll dimensions in millimeters NOTES Meter body style shown here is of nominal size mm meter 3 meters long cable inclusive Mounting adapter not inclusive 3 The shape of the cable outlet in the gure is a...

Page 31: ...S 193 11 E 31...

Page 32: ...S 193 11 E 32 0 Revised 003 0 Released S 93 E All speci cations are subject to change without notice for improvement...

Reviews: