2-6-(32)
EC Position Compensation
Section 2-6
STEP 2: Setting Conditions for Obtaining Lines
Adjust the line conditions if the lines cannot be found easily or to extract only
lines of a particular angle.
Refer to Cross Points for an outline (page 2-6-(18)).
1.
Select Line conditions.
The Line Conditions Settings Screen will be displayed.
2.
Make the settings for each item.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
STEP 3: Setting the Search Region
Set the region to search for the positioning mark.
Adjust the search region if there are areas that are not to be included in multi-
point searches.
CHECK
When edges are extracted, the pixels at the edges of the screen cannot be
processed accurately. Do not include the outer edges of the screen when set-
ting the search region.
SeeAlso
Refer to page 2-6-(9) under
&LUFOHV
.
1.
Select Search region.
Position0(Multi-points)
Measurement conditions
Line conditions
Search region
Reference registration
Clear
End
Line conditions
Extract level
Line angle 0
Line angle 1
Line angle 2
Line angle 3
:
:
:
:
:
:
:
:
3
OFF
[ 0]
OFF
[ 90]
OFF
[180]
OFF
Position0(Multi-points)
Measurement conditions
Line conditions
Search region
Reference registration
Clear