2-14-(31)
Density Defects
Section 2-14
SeeAlso
Refer to page 2-14-(12) for information on elements.
1.
Select Judgement conditions.
The Judgement Conditions Settings Screen will be displayed.
2.
Set a density deviation value.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
2-14-2-4
Clearing Set Regions
The clear operation is performed separately for each region.
1.
Select the number of the region to be cleared.
A list of selections will be displayed.
Region0(Defect(Deviation))
Inspected region
Reference registration
Judgement conditions
Clear
Judgement conditions
End
:
Density deviation : 64 [127]
Measurement result for the displayed image.
Use as reference for setting conditions.
Select region
Region0
Region1
Region2
Region3
Region4
Region5
Region6
Region7
Measurement conditions
Inspected region
Reference registration
Judgement conditions
Detailed conditions
Clear
Example: Clearing region for Defect (line) measurement