2-7-(9)
Edge Position Compensation
Section 2-7
Noise Width
Set the noise width between 0 and 255 to evaluate noise.
If the density distribution from the position where the edge was first detected
falls to below the edge level within the noise width range, the detected point is
judged as noise. Normally the default noise width setting of 0 is sufficient. If
noise is causing incorrect detection, make this value higher.
Example
Clearing Settings
1.
Select Clear.
A confirmation message will be displayed.
2.
Select Execute.
The settings will be cleared and the initial screen for edge position com-
pensation will return.
Edge level
50%
Edge detection point
Noise width (pixel)
If the density falls below the
edge level within the set range,
the detected edge is
determined to be noise.
Measurement
region
Position compensation 0
Measurement conditions
Region
Reference registration
Judgement conditions
Detailed conditions
Clear
Region will be cleared.
Execute
Cancel
1.Edge pos. comp
Measurement image
Position compensation 0
Position compensation 1
Direction