1-(58)
Basic Operations
Section 1-6
1-6-4
STEP 4: Setting Results Output Methods
This function is used to set the method for outputting measurement results to
an external device.
When measurement is executed, the overall judgement (OK or NG) for the set
data is output to the parallel interface OR signal.
Only results from measurements performed in Run Mode will be output.
Results of measurements executed in Monitor Mode will not be output to an
external device.
Set the processing items for the desired results output as outlined in the fol-
lowing table.
Data to be output
Appropriate
processing items
Judgement (OK or NG) output via a parallel interface
DO Judgement
Measurement output via a parallel interface
DO Data
Measurement in normal format output via a serial interface
Normal Data
Measurement in Host Link format output via a serial interface Host Link Data
Measurement output to a Memory Card
Memory Card Data