6-1-(3)
Parallel Interface
Section 6-1
The communications menu will be displayed.
4.
Select Parallel.
The Communications (Parallel) window will be displayed.
5.
The Communications (Parallel) window will be displayed.
6.
Select End.
The displayed settings will be registered and the screen in (3.) will return.
The following table shows the possible communications settings.
System settings
Camera settings
Communication
Display
Operation settings
Measurement control
Startup mode
Date/Time
System information
Serial
Normal
Host link
Parallel
Ethernet
Communications(Parallel)
ON state
Output control
Output period
Gate ON delay
Gate ON time
Timeout
Num. of delay
End
: NG:ON
: None
:[ 10.0]ms
:[ 1.0]ms
:[ 5.0]ms
:[ 10.0]s
:[ 1]
Item
Settings
ON state
Select whether the OR and DO0 to DO31 signals will
go ON when the judgement is OK or NG.
(The default setting is ON for an NG judgement.)
Output control
None
The Controller outputs the measurement results without
synchronizing with the external device. (This is the
default setting.)
Hand-
shak-
ing
The Controller outputs the measurement results while
synchronizing the transmission with the external device.
Sync.
output
The Controller outputs the measurement results while
synchronizing with processing on the line. The number
of STEP signals specified for the Number of delays set-
ting is ignored and measurement results are output on
the next STEP signal.
Output period
(Effective only when
output control is set to
None.)
Set the period for outputting the measurement result.
Set a value between 2.0 and 10,000.0 ms that is
greater than the “Gate ON delay + Gate ON time,” and
less than the measurement interval. If the period is
longer than the measurement interval, the output timing
will fall behind as the measurements are repeated. The
default setting is 10.0 ms.