2-9-(27)
Circle Position Compensation
Section 2-9
Edge Pitch
The edge pitch setting is enabled only when black defect, white defect, or edge
are selected as the mode under Measurement conditions.
Set the pitch to obtain the density difference. (1 to 9 (1*))
Example:Mode: Black defect,
Edge pitch: 2
Number of Circles
Select the number of circles for detecting the rotation positioning tag. (1 or 2
(1*)) The number of circles that can be drawn on the Model Registration
Screen will be limited to the number set here.
If the number is set to 2, the detection accuracy will increase but processing
will take longer.
Changing to Other Modes (Clearing Settings)
The settings must be cleared before changing to another mode.
The settings method is the same as for Not Rotate. Refer to page 2-9-(8).
Compares the density with a point two pixels away.