Page 1: ...Industrial PC Platform NY series Industrial Monitor User s Manual NYM15W C100 NYM15W C106 NYM12W C100 NYM12W C106 Industrial Monitor W554 E2 03 ...

Page 2: ...tion has been taken in the preparation of this manual Nevertheless OMRON assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of the information contained in this publica tion Trademarks Sysmac and SYSMAC are trademarks or registered trademarks of OMRON Corporation in Japan and other countries for OMRON factory automation products Wi...

Page 3: ...of electrical sys tems an electrical engineer or the equivalent Personnel in charge of introducing Factory Automation systems Personnel in charge of designing Factory Automation systems Personnel in charge of installing and maintaining Factory Automation systems Personnel in charge of managing Factory Automation systems and facilities Applicable Products This manual covers the following Industrial...

Page 4: ...ance and Disposal 16 Precautions for Correct Use 17 Storage Installation and Mounting 17 Wiring 17 Actual Operation and Operation 17 Cleaning and Maintenance 18 Regulations and Standards 19 Conformance to EU Directives 19 Conformance to KC Standards 20 Conformance to UL and CSA Standards 20 Related Manuals 21 Related Industrial PC Manuals 21 Related Industrial PC Without Operating System Manuals 2...

Page 5: ... 10 2 4 1 DVI Cables 2 10 2 4 2 USB Type A to USB Type B Cables 2 11 2 4 3 NY Monitor Link Cables 2 12 2 4 4 Power Supply 2 13 Section 3 Software 3 1 Operating Systems 3 2 3 1 1 Touch Functionality 3 2 3 1 2 Determine Your Version of the Windows Operating Systems 3 3 3 2 Support Software 3 4 3 2 1 Overview IPC Support Software for Windows 3 4 3 2 2 Industrial Monitor Utility 3 5 3 2 3 Industrial M...

Page 6: ...Industrial Monitor 5 16 5 3 Wire 5 17 5 3 1 Ground 5 17 5 3 2 Wire the Power Connector 5 24 5 4 Connect 5 26 5 4 1 Connector Identification 5 26 5 4 2 Connection Procedure 5 27 5 5 Initial Power ON 5 28 5 5 1 Initial Power ON Procedure 5 28 Section 6 Operating Procedures 6 1 Touchscreen Operation 6 2 6 2 Power ON Power OFF Standby 6 3 6 3 Support Software and Product Information 6 4 6 4 React to P...

Page 7: ...Index CONTENTS 5 NY series Industrial Monitor User s Manual W554 ...

Page 8: ...CONTENTS 6 NY series Industrial Monitor User s Manual W554 ...

Page 9: ...photos of the package and save them Inform your supplier immediately 2 Open the package Ensure not to damage the contents 3 Ensure that all items are present Additional Information Refer to 5 1 2 Items Supplied with the Product for the items supplied Note This illustration is provided as a sample It will not literally appear in this manual Item Explanation Item Explanation A Level 1 heading E Spec...

Page 10: ...e Precautions on what to do and what not to do to ensure proper operation and performance Additional Information Additional information to read as required This information is provided to increase understanding or make operation easier Version Information Information on differences in specifications and functionality between different versions Manual Information 8 NY series Industrial Monitor User...

Page 11: ... provided that in no event shall Omron be re sponsible for warranty repair indemnity or any other claims or expenses regarding the Products un less Omron s analysis confirms that the Products were properly handled stored installed and main tained and not subject to contamination abuse misuse or inappropriate modification Return of any Products by Buyer must be approved in writing by Omron before s...

Page 12: ...TEM Disclaimers Performance Data Data presented in Omron Company websites catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty It may represent the result of Omron s test conditions and the user must correlate it to actual application requirements Actual per formance is subject to the Omron s Warranty and Limitations of Liab...

Page 13: ... property damage Symbols The circle and slash symbol indicates operations that you must not do The specific operation is shown in the circle and explained in text This example indicates prohibiting disassembly The triangle symbol indicates precautions including warnings The specific operation is shown in the triangle and explained in text This example indicates a precaution for electric shock The ...

Page 14: ...serious injury or for emergency stop switches Water or other liquid present on the touchscreen surface may create false touch behavior and unexpected operation Wipe away liquid on the touchscreen before operation Disassembly and Dropping Do not attempt to disassemble repair or modify the product in any way Do ing so may result in malfunction or fire Installation Always connect to a ground of 100 Ω...

Page 15: ...oduct take appropriate actions to avoid communication failures or damage to the mentioned ports Industrial PC Platform Product Non isolated Device Non isolated Interface 24 VDC 0 VDC Operation When using a system with multiple touchscreens multiple users can per form simultaneous operations Make sure that this can not result in unin tended actions Safety Precautions 13 NY series Industrial Monitor...

Page 16: ...duct Otherwise the product burning failure or malfunction may occur Cover the product or take other suitable countermeasures especially during wiring work Wiring Follow the instructions in the manual to correctly perform connector wiring and insertion Double check all wiring and connector insertion before turning ON the power supply Always ensure connectors and cables are completely locked in plac...

Page 17: ...se the touchscreen functionality to be disabled Remove the conductive object and cycle the power supply to restore the touchscreen functionality Operation Do not carry out the following operations when accessing a USB device or an SD Memory Card Turn OFF the power supply of the product Press the power button of the host PC Remove a USB device Confirm the safety of the system before using the touch...

Page 18: ...s in applications where the product is subject to contact with oil or water As the rubber gasket will deteriorate shrink or harden depending on the operating environment pe riodical inspection is necessary Precautions for Safe Use 16 NY series Industrial Monitor User s Manual W554 ...

Page 19: ... radioactivity Locations close to power lines Always touch a grounded piece of metal to discharge static electricity from your body before starting an installation or maintenance procedure The backlight has a finite life and if that is exceeded the product may fail or malfunction Check the brightness periodically and if necessary replace the product Wiring Always ensure the rated supply voltage is...

Page 20: ...Maintenance Do not use corrosive substances to clean the product Turn OFF the product or disable the touchscreen for cleaning with water Precautions for Correct Use 18 NY series Industrial Monitor User s Manual W554 ...

Page 21: ...curs the user may be required to take appropriate meas ures Applicable Directive EMC Directive EMC Directive OMRON devices that comply with EU Directives also conform to the related EMC standards so that they can be more easily built into other devices or the overall machine The actual products have been checked for conformity to EMC standards Applicable EMC Electromagnetic Compatibility standards...

Page 22: ... to UL and CSA Standards Some Industrial PC Platform products comply with UL and CSA standards If you use a product that complies with UL or CSA standards and must apply those standards to your machinery or devices refer to this manual This manual provides the application conditions for complying with the standards If the product is used in a manner not specified in the Instruction Sheet or in the...

Page 23: ...information with features hardware overview soft ware overview specifications mounting wiring connecting oper ating and maintaining the Industrial Panel PC An introduction to the Industrial Panel PC is provided along with the following information Overview Hardware Software Specifications Installation Operating Procedures Maintenance Related Industrial PC Without Operating System Manuals This tabl...

Page 24: ...ith Machine Automation Control Soft ware Industrial Box PC This includes introductory information with features hardware overview specifi cations mounting wiring connecting operating and maintaining the Box PC An introduction to the In dustrial Box PC with Ma chine Automation Control Software Box PC is pro vided along with the fol lowing information Overview Hardware Specifications Installation Op...

Page 25: ...d IPC Programmable Multi Axis Controller Manuals This table contains the related manuals of other Industrial PC with Programmable Multi Axis Controller products Manual name Cat No Model num bers Application Description Industrial PC with Program mable Multi Axis Control ler Hardware User s Man ual W580 NY512 A 00 1XX 13 X Learning all basic information about the Industrial PC with Programmable Mul...

Page 26: ...n ments IPC Industrial PC Sysmac OMRON s brand name of the product family for the industrial automation equip ment Hardware Term Abbreviation Description DVI Digital Visual Interface DVI D A Digital Visual Interface with only Digital signals NYML NY Monitor Link interface with video signals and USB signals USB Universal Serial Bus Software Term Abbreviation Description API Application Programming ...

Page 27: ... the manual W554 E2 03 Cat No Revision code Revision code Date Revised content 03 June 2017 Added NY Monitor Link Minor modifications 02 December 2016 UL implementation KC Standard implementation Minor modifications 01 September 2016 First release Revision History 25 NY series Industrial Monitor User s Manual W554 ...

Page 28: ...Revision History 26 NY series Industrial Monitor User s Manual W554 ...

Page 29: ... in this Manual Operating Procedures Specifications Installation Software Hardware Overview 1 2 3 4 5 6 1 2 3 4 6 5 1 7 7 Maintenance A Sections in this Manual 27 NY series Industrial Monitor User s Manual W554 ...

Page 30: ...Sections in this Manual 28 NY series Industrial Monitor User s Manual W554 ...

Page 31: ... 1 Intended Use 1 2 1 2 Hardware Features 1 3 1 3 ID Information Label 1 4 1 4 Product Configuration 1 5 1 5 Industrial PC Platform Overview 1 6 1 5 1 Industrial Monitor 1 6 1 5 2 Industrial Box PC 1 7 1 5 3 Industrial Panel PC 1 7 1 1 NY series Industrial Monitor User s Manual W554 1 ...

Page 32: ...ttings of both the LCD backlight and the indicator LEDs This allows the monitor to be configured for the required installation environment The Industrial Monitor additionally includes a USB hub to allow USB slave devices to be added at the monitor location Peripheral components such as a keyboard mouse or camera can be attached to the monitor and used to control or be controlled by the operating s...

Page 33: ...l Use the Monitor Utilities to control the Monitor s LCD brightness DVI D visual interface The video interface for the Monitor is provided with a DVI connector for connection to the host PC USB Type B port for host PC The USB Type B port supports USB2 0 specifications This port allows the host PC to communicate with multiple internal USB devices within the Monitor as well as external devices conne...

Page 34: ...PCs with a custom logo 1 E Standards and QR code The applicable standards and a QR code for OMRON internal use F LOT number and serial number Production details consisting of The lot number of the Industrial Monitor in the format DDMYY DDMYY with Month number 1 to 9 for January to September X for October Y for November and Z for December For use by OMRON Serial number 4 digits 1 Refer to 1 4 Produ...

Page 35: ...h item in the model type has a specific meaning N Y M 1 2 3 4 5 6 7 8 Item Description Option 1 Series name NYM NY series Industrial Monitor 2 Display size diagonal 12 12 1 inches 15 15 4 inches 3 Display ratio W Wide 4 Touchscreen C Projected Capacitive Touch type 5 Frame type 1 Aluminum frame black 6 Design 0 Standard 7 Build in options 0 None 6 NY Monitor Link 8 Logo 0 OMRON 2 Customization 1 O...

Page 36: ...he standalone Industrial Box PC to the touchscreen Industrial Monitor is engineered with long life components and built to the most advanced design standards The following sections introduce Industrial PC Platform products 1 5 1 Industrial Monitor The Industrial Monitor is of key importance at the interface between operator and system The Indus trial Monitor is efficient effective and highly visib...

Page 37: ...orated without the need for wholesale redesign 1 5 3 Industrial Panel PC The Industrial Panel PC intelligently combines the functionality of the Industrial Box PC and Industrial Monitor No cables are used between the two components which ensures optimal signal distribution and reliable operation in industrial environments 1 Overview 1 7 NY series Industrial Monitor User s Manual W554 1 5 Industria...

Page 38: ...1 Overview 1 8 NY series Industrial Monitor User s Manual W554 ...

Page 39: ... 1 Logo LED 2 5 2 2 2 Status LED Indicator 2 5 2 3 Connectors 2 6 2 3 1 Power Connector 2 6 2 3 2 DVI D Connector Optional 2 7 2 3 3 NY Monitor Link Connector Optional 2 7 2 3 4 USB Type A Connector 2 8 2 3 5 USB Type B Connector Optional 2 9 2 4 Optional Hardware 2 10 2 4 1 DVI Cables 2 10 2 4 2 USB Type A to USB Type B Cables 2 11 2 4 3 NY Monitor Link Cables 2 12 2 4 4 Power Supply 2 13 2 1 NY ...

Page 40: ...al Monitor B D A C Item Name Description A Logo Backlit logo with adjustable brightness B Status LED Indicator Multi colored LED to indicate power and connection status with adjustable brightness C ID Information Label Label containing Model ID LOT No and other product specific information Refer to 1 3 ID Information Label on page 1 4 for label details D Touchscreen Multi touch LCD display 2 Hardw...

Page 41: ... 2 USB connectors to connect external USB slave devices D USB Type B Connector USB connector for connection with the host PC Only for Industrial Monitors with a DVI D connector E Mounting Brackets 8 retractable mounting brackets to secure the Industrial Monitor on a mounting surface F Ground Terminal Terminal connection for grounding of the Industrial Monitor G NYML Connector 1 NY Monitor Link con...

Page 42: ... LED indicators on the front of the product B A Item LED Description A Logo LED LED to backlight the logo B Status Indicator LED Indicates the operating condition of the Industrial Monitor 2 Hardware 2 4 NY series Industrial Monitor User s Manual W554 ...

Page 43: ...ormation about the operating condition of the Industrial Monitor Color Status Meaning None Not lit The Status LED is not lit in following situations The 24 VDC power is not supplied Normal operation Green Blinking The Status LED is blinking in following situations The host PC is in standby mode The host PC power is not supplied The DVI cable or the NY Monitor Link cable is not connected Red Lit Th...

Page 44: ...pply 24 VDC power to the Monitor The power connector is supplied with the Monitor Additional Information Refer to 4 2 1 Power Connector Specifications on page 4 4 for specifications Refer to 5 3 2 Wire the Power Connector on page 5 24 for wiring details Refer to 5 4 Connect on page 5 26 for connection details 2 Hardware 2 6 NY series Industrial Monitor User s Manual W554 ...

Page 45: ... 4 2 2 DVI D Connector Specifications on page 4 5 for specifications Refer to 5 4 Connect on page 5 26 for connection details 2 3 3 NY Monitor Link Connector Optional Depending on the product configuration this NY Monitor Link connector is available The NY Monitor Link interface connector connects an OMRON Industrial PC to the OMRON Industrial Monitor Industrial PC Industrial Monitor 2 Hardware 2 ...

Page 46: ... page 5 26 for connection details 2 3 4 USB Type A Connector The Universal Serial Bus USB Type A connectors provide a connection point on the Industrial Moni tor for USB slave devices Additional Information Refer to 4 2 4 USB Type A Connector Specifications on page 4 9 for specifications Refer to 5 4 Connect on page 5 26 for connection details 2 Hardware 2 8 NY series Industrial Monitor User s Man...

Page 47: ...es this interface to access the internal touchscreen functions as well as external devices plugged into the USB Type A connectors Additional Information Refer to Product Configuration for configuration details Refer to 4 2 5 USB Type B Connector Specifications on page 4 10 for specifications Refer to 5 4 Connect on page 5 26 for connection details 2 Hardware 2 9 NY series Industrial Monitor User s...

Page 48: ...performance of any other brand of DVI cable Model Appearance Cable length Specifications NY000 AC00 2M 2 m Supports DVI D Minimum bend radius 36 mm NY000 AC00 5M 5 m DVI Cable Clearance The DVI cable requires a minimum clearance of 90 mm from the connector entry to prevent excessive strain on the connector and cable assembly 90 mm 2 Hardware 2 10 NY series Industrial Monitor User s Manual W554 ...

Page 49: ...Cable length Specifications FH VUAB 2M 2 m USB 2 0 Minimum bend radius 25 mm FH VUAB 5M 5 m USB Type A to USB Type B Cable Clearance The USB Type A to USB Type B cable requires a minimum clearance of 60 mm from the connector entry to prevent excessive strain on the connector and cable assembly 60 mm 2 Hardware 2 11 NY series Industrial Monitor User s Manual W554 2 4 Optional Hardware 2 2 4 2 USB T...

Page 50: ...outer diameter 7 6 mm 7 7 mm 9 0 mm Maximum bending radius of cable in a fixed position 31 mm 31 mm 90 mm Maximum temperature for a cable in a fixed position 60 C 60 C 80 C RJ45 connectors Manufacturer Stewart Connector Stewart Connector Lapp Partnumber SS39200 027 or SS39200 030 SS39200 027 or SS39200 030 21700600 T568A or 21700601 T568B Connector length 30 mm 30 mm 50 mm Additional Information W...

Page 51: ...tage 24 VDC Additional Information Refer to 4 1 2 General Electrical Specifications on page 4 3 for power consumption de tails Refer to the OMRON website for specifications and manuals of the S8VK G Note that the power consumption details of the Monitor determine the minimum power rating of your power supply 2 Hardware 2 13 NY series Industrial Monitor User s Manual W554 2 4 Optional Hardware 2 2 ...

Page 52: ...2 Hardware 2 14 NY series Industrial Monitor User s Manual W554 ...

Page 53: ...ng Systems 3 3 3 2 Support Software 3 4 3 2 1 Overview IPC Support Software for Windows 3 4 3 2 2 Industrial Monitor Utility 3 5 3 2 3 Industrial Monitor Brightness Utility 3 8 3 2 4 Industrial PC Tray Utility 3 10 3 3 Software for Developers 3 13 3 3 1 Overview IPC Developer Software for Windows 3 13 3 3 2 Industrial Monitor API 3 14 3 1 NY series Industrial Monitor User s Manual W554 3 ...

Page 54: ...nitor Requirements To use touch functionality The Operating System has to support tablet PC features Touch functionality drivers have to be installed Calibration The touch functionality is calibrated for the default screen resolution Calibrate the display when setting a different resolution results in displaying your content on only a part of the display Additional Information Refer to 4 3 Display...

Page 55: ...s An overview of your System Information will appear including the Windows Operating System details Windows 10 To determine your version of the Windows Operating System 1 Select the Search Button 2 Enter System Information in the search box 3 Select System Information in the pop up that appears An overview of your System Information will appear including the Windows Operating System details 3 Soft...

Page 56: ...Monitor Brightness Utility Industrial PC Tray Utility Industrial Box PC Industrial PC Support Utility Industrial PC Tray Utility Industrial Panel PC Industrial Monitor Utility Industrial Monitor Brightness Utility Industrial PC Support Utility Industrial PC Tray Utility Select and download the utilities required from the OMRON download website Additional Information An internet connection is requi...

Page 57: ...eo Status C Monitor Settings Provides several setting adjustments to control the operation of the selected Industrial Monitor D Backlight Brightness Ad justment 2 Use the slider to control the brightness of the selected Industrial Monitor E Logo Brightness Adjust ment Use the slider to control the brightness of the Logo LED Refer to 2 2 1 Logo LED on page 2 5 for details about the Logo LED F Statu...

Page 58: ...at is connected to an OMRON Industrial Monitor This monitor utility can be used with Windows Embedded Standard 7 Windows 10 Additional Information This monitor utility does not support 3rd party monitors Installation The Industrial Monitor Utility is pre installed on the Industrial Box PC and the Industrial Panel PC Download the Industrial Monitor Utility from the OMRON download website for re ins...

Page 59: ... Description Info Connected A new monitor connected USB cable connected Monitor powered ON Warning Not Connected Monitor disconnected USB cable disconnected Monitor powered OFF Warning Video Discon nected DVI cable disconnected or NY Monitor Link cable disconnected Warning No Signal DVI cable connected but no signal detected Logging There is logging in the Windows event log of the following utilit...

Page 60: ... a very low backlight brightness setting 15 0 the displayed information might not be visible in an environment with high ambient light conditions This prevents brightness adjustments with the In dustrial Monitor Brightness Utility Additional Information To adjust the backlight brightness when the brightness setting is set too low Bring the Monitor in a low ambient light environment Lighten the dis...

Page 61: ...rial PC Tray Utility or from the Windows Start Menu select Omron and then Industrial Monitor Brightness Utility Additional Information Refer to 3 2 4 Industrial PC Tray Utility on page 3 10 for Industrial PC Tray Utility details Configuration Configuration is not required This Industrial Monitor Brightness Utility will detect and support all con nected NY series Industrial Monitors Logging There i...

Page 62: ... overall state of all installed OMRON utilities in the icon in the system tray area Display a menu that can start all installed utilities and show the state of each installed utility Display notification messages in popup windows that inform the user about the state of applications or hardware The Industrial PC Tray Utility displays the messages provided by installed OMRON utilities Refer to the O...

Page 63: ...y Refer to About the Industrial PC Tray Utility on page 3 11 for details The Exit entry E closes the utility About the Industrial PC Tray Utility The About window shows the version of the Industrial PC Tray Utility and copyright information Status Indicators on Icons The following table provides the indicator details of the Industrial PC Tray Utility Overlay type Icon Description None No OMRON uti...

Page 64: ...anually start the Industrial PC Tray Utility 1 Locate the Industrial PC Tray Utility using the Windows Start menu or the Windows search box 2 Use the option Run as administrator to activate the Industrial PC Tray Utility Additional Information The procedure to use Run as administrator is For Windows 10 using the Start menu Rightclick the Industrial PC Tray Utility select More and then Run as admin...

Page 65: ...system Product Developer software Industrial Monitor Industrial Monitor SDK Industrial Monitor API Industrial Box PC Industrial PC System SDK Industrial PC System API Industrial Panel PC Industrial Monitor SDK Industrial Monitor API Industrial PC System SDK Industrial PC System API Select and download the software required from the OMRON download website 3 Software 3 13 NY series Industrial Monito...

Page 66: ... Industrial Panel PC display Retrieve product status information Set the brightness of the Status LED indicator Set the brightness of the backlight Set the brightness of the Logo LED Set the touch points of the monitor Store settings Restore to factory defaults The API makes use of the included Industrial Monitor Service to manage all Industrial Monitors con nected via USB Installation The Industr...

Page 67: ...tions 4 4 4 2 2 DVI D Connector Specifications 4 5 4 2 3 NY Monitor Link Connector Specifications 4 7 4 2 4 USB Type A Connector Specifications 4 9 4 2 5 USB Type B Connector Specifications 4 10 4 3 Display Specifications 4 11 4 4 Environmental Specifications 4 12 4 4 1 Operation Environment Specifications 4 12 4 4 2 Temperature and Humidity Specifications 4 13 4 4 3 Recycling Specifications 4 14 ...

Page 68: ...imensions and weights Z Y X R Item Specifications 12 1 Inch 1 15 4 Inch 1 Dimensions Width X 332 mm Height Y 234 mm Depth Z 66 mm Width X 401 mm Height Y 277 mm Depth Z 66 mm Monitor thickness on top of panel Rim thickness R 8 0 mm Weight 3 3 kg 4 3 kg 1 Refer to 1 4 Product Configuration on page 1 5 for details 4 Specifications 4 2 NY series Industrial Monitor User s Manual W554 ...

Page 69: ...unding method Ground to less than 100 Ω Power consumption With DVI D interface 25 W max With NY Monitor Link in terface 30 W max 31 W max Inrush current At 24 VDC 5 A 10ms max Overvoltage category JIS B3502 and IEC 61131 2 Category II EMC immunity level IEC 61132 2 Zone B 1 Refer to 1 4 Product Configuration on page 1 5 for details 4 Specifications 4 3 NY series Industrial Monitor User s Manual W5...

Page 70: ...tact type FKCT 2 5 2 STF 5 08 BK 1711707 1 2 The pin layout represents the power connector on the Industrial Monitor Pin Description 1 24 VDC 2 0 VDC Item Specifications Conductor isolation rating 90 C Termination rating 90 C Additional Information Refer to 5 3 2 Wire the Power Connector on page 5 24 for wiring details Refer to 5 3 1 Ground on page 5 17 for grounding details Refer to 5 4 Connect o...

Page 71: ...hannel The Industrial Monitor can detect if the DVI cable is not connected or that the host PC is not powered or the DVI port on the host PC is disabled Item Specifications Video interface Digital only Resolution 1 280 x 800 pixels at 60 Hz Maximum DVI cable length 5 m Additional Information Refer to 5 3 1 Ground on page 5 17 for grounding details Refer to 5 4 Connect on page 5 26 for connect deta...

Page 72: ...ata DDC data 8 Not connected 9 TMDS data 1 Digital green link 1 10 TMDS data 1 Digital green link 1 11 0 VDC TMDS data 1 3 shield 12 Not connected 13 Not connected 14 5 V Power for monitor DDC interface 15 0 V Return for pin 14 16 HPD Hot plug detect 17 TMDS data 0 Digital blue link 1 and digital sync 18 TMDS data 0 Digital blue link 1 and digital sync 19 0 VDC TMDS data 0 5 shield 20 Not connecte...

Page 73: ...num foil Maximum cable length between Industrial PC and Industrial Monitor 100 m Topology Line direct connection only 1 Video resolution 1 280 x 800 pixels at 60 Hz Data throughput rate 280 Mbps max 1 Use a direct connection between the OMRON Industrial PC and the OMRON Industrial Monitor Do not use Ethernet switches Ethernet hubs Daisy chain connections The NY Monitor Link connector locks automat...

Page 74: ...olor Status Description A Con nected Yellow Not lit Not connected Lit Connected USB communication active B Video Green Not lit No video signal Blinking Video signal present Lit Encrypted video signal present Video output is not supported for encrypted video 4 Specifications 4 8 NY series Industrial Monitor User s Manual W554 ...

Page 75: ...trial PC Details of the USB Type A interface connectors are provided below 1 2 HOST Interface Connector Details 1 USB 2 0 500 mA maximum current 5 m maximum cable length 2 Additional Information Refer to 5 3 1 Ground on page 5 17 for grounding details Refer to 5 4 Connect on page 5 26 for connection details 4 Specifications 4 9 NY series Industrial Monitor User s Manual W554 4 2 Connector Specific...

Page 76: ...screen func tions as well as other external devices plugged into the USB Type A connectors Details on the USB Type B interface connector are provided below Item Details USB Type B connector USB 2 0 5 m maximum cable length Additional Information Refer to 5 3 1 Ground on page 5 17 for grounding details Refer to 5 4 Connect on page 5 26 for connection details 4 Specifications 4 10 NY series Industri...

Page 77: ...on Touch accuracy 1 5 4 5mm Multitouch Up to 5 simultaneous touches Features Water detection 4 hand palm rejection 5 gloves 6 Backlight Life 50 000 hours minimum 7 Brightness adjust ment 8 200 levels 1 Refer to 1 4 Product Configuration on page 1 5 for details 2 There may be some defective pixels in the display This is not a fault as long as the number of defective light and dark pixels fall withi...

Page 78: ...IEC 61000 4 4 2kV power lines Vibration resistance during opera tion Conforms to IEC 60068 2 6 5 to 8 4 Hz with 3 5 mm single amplitude and 8 4 to 150 Hz with 9 8 m s for 10 times each in X Y and Z directions Shock resistance during operation Conforms to IEC 60068 2 27 147 m s 3 times each in X Y and Z directions Degree of protection Front of product IP65 3 Pollution degree 2 or less Conforms to J...

Page 79: ...0 10 20 30 40 50 60 70 80 90 100 Operating temperature humidity range The ambient operating temperature specifications do not depend on the mounting angle orientation or display size Store the Industrial Monitor within the ambient temperature and humidity ranges as shown in follow ing graph Humidity Storage temperature humidity range Temperature C 0 10 20 30 40 50 60 70 80 90 100 30 20 10 0 10 20 ...

Page 80: ...ait 45 to 90 0 to 55 C 90 to 135 0 to 55 C 1 Refer to 1 4 Product Configuration on page 1 5 for model details 90 to 135 45 to 90 0 to 45 Additional Information Refer to 4 4 2 Temperature and Humidity Specifications on page 4 13 for graph details 4 4 3 Recycling Specifications The following table provides recycling information for the Industrial Monitor Part Recycle Specifications Boards and other ...

Page 81: ...ture 5 6 5 2 4 Humidity 5 8 5 2 5 Vibration and Shock 5 8 5 2 6 Atmosphere 5 9 5 2 7 Electrical Environment 5 9 5 2 8 Prepare the Mounting Surface 5 14 5 2 9 Mount the Industrial Monitor 5 16 5 3 Wire 5 17 5 3 1 Ground 5 17 5 3 2 Wire the Power Connector 5 24 5 4 Connect 5 26 5 4 1 Connector Identification 5 26 5 4 2 Connection Procedure 5 27 5 5 Initial Power ON 5 28 5 5 1 Initial Power ON Proced...

Page 82: ...re is any visible damage Take photos of the package and save them Inform your supplier immediately 2 Open the package Ensure not to damage the contents 3 Ensure that all items are present Additional Information Refer to 5 1 2 Items Supplied on page 5 3 for the items supplied 5 Installation 5 2 NY series Industrial Monitor User s Manual W554 ...

Page 83: ...nitor Industrial Monitor Documentation Safety Precautions sheets English and Japanese EU Compliance sheet Standards and Certifications sheet Bag with power connector Industrial Monitor PC 5 Installation 5 3 NY series Industrial Monitor User s Manual W554 5 1 Unpack 5 5 1 2 Items Supplied ...

Page 84: ...malfunction Precautions for Correct Use Do not operate or store the Monitor in the following locations Operation may stop or malfunc tions may occur Locations subject to direct sunlight Locations subject to temperatures or humidity outside the range specified in the specifica tions Locations subject to condensation as the result of severe changes in temperature Locations subject to corrosive or fl...

Page 85: ...onitor can be mounted in a landscape A or portrait B orientation Do not install the Industrial Monitor in any of the following orientations 5 Installation 5 5 NY series Industrial Monitor User s Manual W554 5 2 Mount 5 5 2 2 Product Orientation ...

Page 86: ...12 for temperature specifications Allow space to accommodate for the bending radius of the cables Refer to 2 4 1 DVI Cables on page 2 10 2 4 2 USB Type A to USB Type B Cables on page 2 11 2 4 3 NY Monitor Link Cables on page 2 12 for cable bending requirements Provide enough space for good air flow and ensure the following minimum distances are observed around the sides of the Industrial Monitor f...

Page 87: ... from other devices wiring ducts etc Do not mount the Monitor in the wrong direction e g vertically or upside down Doing so may cause abnormal heating in the Monitor Do not install the Monitor directly above any heat generating equipment such as heaters or transformers Do not install the Monitor in a location exposed to direct sunlight Natural Cooling OMRON product OMRON product Forced Ventilation...

Page 88: ...ty Rapid temperature changes can cause condensation to occur resulting in malfunctioning due to short circuiting When there is a possibility of this occurring take measures against condensation such as leaving the Monitor power ON at night or installing a heater in the control panel to keep it warmer Moisture absorber Power ON Control panel Heater Examples of Measures against Condensation OMRON pr...

Page 89: ...ic solvents use a panel with an airtight structure Be careful of temperature increases inside the panel In locations exposed to corrosive gas purge the air inside the panel to clear the gas and then pres surize the inside of the panel to prevent gas from entering from outside In locations where flammable gas is present either use an explosion protected construction or do not use the Monitor 5 2 7 ...

Page 90: ...supply feed section Use an isolating transformer to significantly reduce noise between the Monitor and the ground In stall the isolating transformer between the Monitor power supply and the noise filter and do not ground the secondary coil of the transformer Keep the wiring between the transformer and the Monitor as short as possible twist the wires well and keep the wiring separate from high volt...

Page 91: ... lines and power lines DC signals and AC signals High frequency devices such as Inverters and signal lines communications Routing of Wiring Observe the following points when wiring power supply and signal cables When routing signal cables with differing characteristics through the same duct always keep them separated As much as possible avoid routing multiple power supply lines through the same du...

Page 92: ...ltage devices Wire and install them as far apart as possible Either install the Monitor a minimum of 200 mm away from high voltage lines or power lines or place the high voltage lines or power lines in metal tubing and completely ground the metal tub ing to 100 Ω or less Example Separating an OMRON product from Power Lines Metal tubing 200 mm 200 mm High voltage power panel Power lines Power lines...

Page 93: ... Industrial Monitor directly into the duct Additional Information Refer to Distance for Cooling on page 5 6 for the minimum required distances It is convenient to use wiring ducts that have the same depth as the Industrial Monitor Duct Product 5 Installation 5 13 NY series Industrial Monitor User s Manual W554 5 2 Mount 5 5 2 7 Electrical Environment ...

Page 94: ... mm Cutout Width X1 383 0 1 mm Cutout Height Y1 259 0 1 mm Panel thickness range 2 Panel thickness range Z1 1 6 to 6 0 mm Panel thickness range Z1 1 6 to 6 0 mm Dimensions Refer to 4 1 1 Dimensions and Weight on page 4 2 for X Y Z and R dimensions 1 Refer to 1 4 Product Configuration on page 1 5 for model details 2 The minimum panel thickness depends on the panel material For the most common mater...

Page 95: ...ness 2 5 to 6 0 mm 2 Create an opening in the mounting surface The table before step 1 gives an overview of the cut out dimensions for the Monitor Prepare a rectangular cut out with the dimensions X1 and Y1 3 Ensure the mounting surface is clean and not warped 5 Installation 5 15 NY series Industrial Monitor User s Manual W554 5 2 Mount 5 5 2 8 Prepare the Mounting Surface ...

Page 96: ...to the mounting surface cut out so the bezel B touches the mounting sur face 3 Loosen the allen bolts 2 of the mounting brackets The mounting brackets are spring loaded and will extend 3 when loose 4 Ensure all mounting brackets extend to overlap the mounting surface 5 Tighten all mounting brackets to a torque of 0 6 N m to maintain water and dust resistance Precautions for Safe Use The mounting p...

Page 97: ... Non isolated Device Non isolated Interface 24 VDC 0 VDC Caution Never ground the 24 VDC side of the power supply This may cause a short circuit The shielding of the communication connectors are directly bonded to the case and to the ground of the Monitor The shield of a communication cable should be terminated to ground at both ends of the cable with a low impedance connection A large surface are...

Page 98: ...es exceeding 1 V Make sure to run the bonding conductor in close proximity to the communication cable The Monitor has a protection ground connection because the metal part of the Monitor outside of the enclosure must be part of the protection grounding of that enclosure for example a cabinet There are no power supply voltages used in the Monitor which require protection grounding 5 Installation 5 ...

Page 99: ...ntial bonding system Star earthing Daisy chain The cable shield connect ed to the connector hood at both ends of the com munications cable Recommended Not recommended Not recommended Additional Information In a country or region where the earthing method is regulated you must comply with the reg ulations Refer to the applicable local and national ordinances of the place where you install the syste...

Page 100: ...e of an equipotential bonding system Connect the main earthing terminal and building structures together with equipotential bonding con ductors and embed the mesh ground line in each floor Connect the ground line of each control panel to the equipotential bonding system Information device Power device Metal duct and pipe Building structure Equipotential bonding conductor Main earthing terminal Ear...

Page 101: ...ectrode is separated by a minimum of 10 m from any other earth electrode of a device that could be a noise source Hub Control panel Other device A device that could be a noise source NY series Industrial Box PC NY series Industrial Panel PC NY series Industrial Monitor 10 m min b Connecting devices and noise sources to a common earth electrode This is an earthing method to connect the device that ...

Page 102: ...to a common earth electrode This earthing method is not recommended because the device that could be a noise source may inter fere electromagnetically with other devices Hub Control panel Other device A device that could be a noise source NY series Industrial Box PC NY series Industrial Panel PC NY series Industrial Monitor 5 Installation 5 22 NY series Industrial Monitor User s Manual W554 ...

Page 103: ...re pre mounted at the Industrial Monitor C B A Remove the pre mounted washers and screw A and then mount the ground connection wire C to the Monitor B using the washers and screw A Tighten the screw with a torque of 1 2 N m max Crimp terminals Use crimp terminals with dimensions X M4 and Y 8 mm max Y X Y X 5 Installation 5 23 NY series Industrial Monitor User s Manual W554 5 3 Wire 5 5 3 1 Ground ...

Page 104: ...ode CEC Canadian Electrical Code international applicable standards Refer to 4 1 2 General Electrical Specifications on page 4 3 for electrical specifications Power Connector Wiring Materials Use the power supply connector that was supplied to connect the power supply to the Industrial Moni tor Select power supply conductors with consideration to the voltage drop and heat generation for the cable ...

Page 105: ... precautions to prevent broken wires When you remove the sheath be careful not to damage the conductor Connect the conductor without twisting the wires Do not weld the conductors Doing so may cause the wires to break with vibration 2 Insert a screwdriver in the small orange groove above the cable opening 1 Push the screw driver 1 to unlock the cable entry and then push the wire all the way to the ...

Page 106: ...tor with NYML connector Item Name Description A Power Supply Connector Power connector with screw fixing B DVI D Connector Digital Visual Interface connector C USB Type A Connectors USB Type A connectors D USB Type B Connector USB Type B connector E no connector F Ground Terminal The ground terminal G NYML Connector NY Monitor Link connector 5 Installation 5 26 NY series Industrial Monitor User s ...

Page 107: ...e to connect the Industrial Monitor 1 Ensure the ground terminal F is connected Refer to 5 3 1 Ground on page 5 17 for ground connection details 2 Connect the power connector A and tighten the screws with a torque of 0 3 N m max using a screwdriver 3 Connect the DVI D connector B to a host PC and tighten the fastening screws or connect the NY Monitor Link connector G to a host PC 4 For an Industri...

Page 108: ...an damage the product or cause burning 3 Supply power to the host PC Windows drivers will automatically install upon detection of the Industrial Monitor The Logo LED will become lit The monitor will display content from the host PC 4 Verify that the host PC is responding to finger touches on the touchscreen of the Industrial Monitor 5 Install the Industrial Monitor Utility and Industrial Monitor B...

Page 109: ... operating procedures for the Industrial Monitor 6 1 Touchscreen Operation 6 2 6 2 Power ON Power OFF Standby 6 3 6 3 Support Software and Product Information 6 4 6 4 React to Product Messages 6 5 6 1 NY series Industrial Monitor User s Manual W554 6 ...

Page 110: ...rojected capacitive technology for the touch operation Only light pres sure is required to activate the touch function Up to 5 simultaneous touches can be detected Multiple simultaneous touch points can be supported in software for advanced touch functions such as zoom rotation and multiple user interaction The touchscreen can ignore hand palm touches while still accepting additional correct touch...

Page 111: ... is touching the surface of the touchscreen Doing so will cause the touchscreen function ality to be disabled Remove the conductive object and cycle the power supply to restore the touchscreen functionality Signals status and operation are provided in the table below Item Product Status LED status Logo LED Status LED No Power OFF Power but no video sig nal DVI D or NY Moni tor Link Standby Power a...

Page 112: ...ndustrial Monitor Utility details Refer to 3 3 2 Industrial Monitor API on page 3 14 for Industrial Monitor API details The connected Industrial Box PC can use the Industrial PC Tray Utility to display the status of the PC but also of the Industrial Monitor Additional Information Refer to 3 2 4 Industrial PC Tray Utility on page 3 10 for Industrial PC Tray Utility details Refer to 6 4 React to Pro...

Page 113: ...ror symbol displayed on the Industrial PC Tray Utility icon indicates a product mes sage To react to a product message 1 Select the Industrial PC Tray Utility icon A pop up window will appear 2 Read the message available in the pop up 3 Refer to 7 2 1 Warning and Error Messages on page 7 5 for all details on the message Perform the actions presented for the message until the Warning or Error is re...

Page 114: ...6 Operating Procedures 6 6 NY series Industrial Monitor User s Manual W554 ...

Page 115: ...n the Touchscreen Surface 7 3 7 1 3 Clean the Monitor 7 3 7 1 4 Check the Gasket Seal 7 4 7 1 5 Keep Software Updated 7 4 7 2 Corrective Maintenance 7 5 7 2 1 Warning and Error Messages 7 5 7 2 2 Windows Event Viewer 7 5 7 2 3 Correct Display Functionality when Nothing is Displayed 7 8 7 2 4 Correct Touchscreen Functionality 7 9 7 1 NY series Industrial Monitor User s Manual W554 7 ...

Page 116: ...or rim Refer to 7 1 4 Check the Gasket Seal on page 7 4 for gasket details Check the ambient environment Temperature and humidity within specifications Noise sources not close to the Industrial Monitor Refer to 4 4 Environmental Specifications on page 4 12 for environmen tal specifications Check installation Industrial Monitor mounted securely Refer to 5 2 Mount on page 5 4 for installation detail...

Page 117: ...e cloth with a neutral cleanser an ap proximately 2 solution wring out the cloth and wipe the Industrial Monitor Remove all residue from gum vinyl or tape when cleaning Precautions for Correct Use Turn OFF the product or disable the touchscreen for cleaning 7 1 3 Clean the Monitor Clean the Monitor periodically in order to keep it in the best operating condition Wipe the Monitor with a dry soft cl...

Page 118: ... the rubber gasket will deteriorate shrink or harden depending on the operating environ ment periodical inspection is necessary 7 1 5 Keep Software Updated Always keep the software of the host PC at the latest released version to ensure stable operation It is specifically important for The operating system The OMRON utilities for the monitor Additional Information Refer to 3 2 Support Software on ...

Page 119: ...ndicator provides information on warnings and errors Additional Information Refer to 2 2 2 Status LED Indicator on page 2 5 for Status details Industrial PC Tray Utility The Industrial PC Tray Utility provides information on warnings and errors The Industrial PC Tray Utility can provide Status information of a connected Industrial Monitor Information from a custom application that uses the Industr...

Page 120: ...ogs and select Application The Event list will display the Events 5 Select the heading Source to sort the event messages per application 6 Scroll to the event you want to investigate Refer to the section Logging of a specific utility for more details 7 Select the event to display details in the Event details window or to take action in the Action overview window 7 Maintenance 7 6 NY series Industr...

Page 121: ...r Current Log The Filter Current Log page opens 3 Input the desired filters and select OK 4 The filtered events will appear in Event list of the Event Viewer Select an event in the Event list to display Event details in the Event details part of the Event Viewer The filtered events are available including the details per event 7 Maintenance 7 7 NY series Industrial Monitor User s Manual W554 7 2 C...

Page 122: ...lity on page 3 5 for brightness details If the Status LED is blinking Check if the host PC is ON and not in standby mode Check if the DVI cable or NY Monitor Link cable is connected If the Status LED is ON Check if the power supply voltage is inside specifications Refer to 4 1 2 General Electrical Specifications on page 4 3 for power supply specifications Check if the ambient temperature is inside...

Page 123: ...nitor Refer to Correct Touchscreen Functionality with Multiple Monitors on page 7 11 for details No Touch Functionality When the touch functionality is not functional Check for water present on the display surface Wipe the display surface with a dry lint free cloth When using gloves ensure to use gloves that are functional with this touchscreen For an Industrial Monitor with a DVI D connector Chec...

Page 124: ...Select the Windows Start Button 2 In the search field input Tablet 3 Select Tablet PC Settings The Tablet PC Settings window opens 4 Select the Calibrate Button A window with lines and a touch indicator will appear 5 Touch the indicator on all locations where it appears When finished a window appears with the question Do you want to save the calibration data 6 Select the Yes Button 7 Check the tou...

Page 125: ...et PC Settings The Tablet PC Settings window opens 4 Select the Setup Button An empty screen appears with only the message Touch this screen to identify it as the touchscreen If this is not the Table PC screen press Enter to move to the next screen To close the tool press Esc 5 Select Enter to move the message to the connected monitor with touch functionality 6 Touch the screen to indicate it is t...

Page 126: ...unctionality if the touch indicator does not appear at the location that you touch Refer to Calibrate Touchscreen on page 7 10 for calibration details The touchscreen functionality is available on the correct monitor 7 Maintenance 7 12 NY series Industrial Monitor User s Manual W554 ...

Page 127: ...I Index I 1 NY series Industrial Monitor User s Manual W554 I ...

Page 128: ... 10 L Logging Event viewer 7 5 Messages 3 7 3 9 Logo LED 2 5 M Messages 7 5 Product 6 5 Mount 5 4 5 16 N NY Monitor Link 2 7 Cable 2 12 LED Indicators 4 8 Specifications 4 7 P Power connector 2 6 Specifications 4 4 Wiring 5 24 5 25 Power OFF 6 3 Power ON 6 3 First time 5 28 Power supply 2 13 Preventive maintenance 7 2 S Scope of delivery 5 3 Standby 6 3 Status 6 4 Status LED 2 5 T Temperature 4 13...

Page 129: ......

Page 130: ... IL 60169 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Kyoto JAPAN OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 OMRON CHINA CO LTD Room 2211 Bank of China T...

Reviews: