6-2-(89)
Normal Serial Interface
Section 6-2
Labeling (Settings Data)
Note
If these settings are changed, one rectangular region will be set and the previ-
ously drawn figures will be deleted.
Data
Details
Settings
data
31
Measurement image
0: Image 0
1: Image 1
32
Coordinate mode
0: After scroll, calibration OFF
1: Before scroll, calibration OFF
2: After scroll, calibration ON
3: Before scroll, calibration ON
33
Measurement region Upper left X (0 to 511) (See note.)
34
Upper left Y (0 to 483) (See note.)
35
Lower right X (0 to 511) (See note.)
36
Lower right Y (0 to 483) (See note.)
37
Binary level
Upper limit (0 to 255)
38
Lower limit (0 to 255)
39
Reverse binary level
0: Not reversed
1: Reversed
40
Area
Upper limit (0.000 to 9,999,999.999)
41
Lower limit (0.000 to 9,999,999.999)
42
Filling up holes
0: OFF
1: ON
43
Sort
0: Area descending 1: Area ascending
2: X gravity descending 3: X gravity ascending
4: Y gravity descending 5: Y gravity ascending
44
Outside trimming
0: OFF
1: ON
45
Label number (0 to 2,499)
46
Number of labels
Upper limit (0 to 2,500)
47
Lower limit (0 to 2,500)
48
Area
Upper limit (0.000 to 9,999,999.999)
49
Lower limit (0.000 to 9,999,999.999)
50
Gravity X
Upper limit (-9,999.999 to 9,999.999)
51
Lower limit (-9,999.999 to 9,999.999)
52
Gravity Y
Upper limit (-9,999.999 to 9,999.999)
53
Lower limit (-9,999.999 to 9,999.999)