6-3-(11)
Host Link Serial Interface
Section 6-3
0023: Read Scene Number
Reads the scene number currently being used.
CHECK
Write Flags: Each time that data is output, the write flags are switched
between “0000" and “1111". The status of these bits can be monitored to see
when data has been written.
0030: Switch Scene Group (Specific Scene Group Number)
Switches the scene group number to the specified scene group number.
0031: Switch Scene Group (Increment Scene Group Number by 1)
Increments the scene group number currently being used. If the current scene
group number is 31, the number will rollover to scene group 0.
0032: Switch Scene Group (Decrement Scene Group Number by 1)
Decrements the scene group number currently being used. If the current
scene group number is 0, the number will rollover to scene group 31.
0033: Read Scene Group Number
Reads the scene group number currently being used.
Read
Area
word
Bits
Contents
15 to 12
11 to 8
7 to 4
3 to 0
+0
0000
0000
0010
0011
Command code
Write
Area
word
Bits
Contents
15 to 12
11 to 8
7 to 4
3 to 0
+0
Write
flags
0000
0000
0000
Write flag
+1
0000
0000
10
1
digit
10
0
digit
Scene number (00 to
31)
Read
Area
word
Bits
Contents
15 to 12
11 to 8
7 to 4
3 to 0
+0
0000
0000
0011
0000
Command code
+1
----
----
10
1
digit
10
0
digit
Scene group number
(00 to 31)
Read
Area
word
Bits
Contents
15 to 12
11 to 8
7 to 4
3 to 0
+0
0000
0000
0011
0001
Command code
Read
Area
word
Bits
Contents
15 to 12
11 to 8
7 to 4
3 to 0
+0
0000
0000
0011
0010
Command code
Read
Area
word
Bits
Contents
15 to 12
11 to 8
7 to 4
3 to 0
+0
0000
0000
0011
0011