2-34-(14)
Trend Monitor
Section 2-34
2-34-5
Changing Detailed Conditions
The items displayed on the Trend Monitor and the timing of warnings can be
changed. Change these detailed conditions as required.
The asterisk (*) indicates the default setting.
Note
1.
If the recording interval is set to 2 or higher, the minimum and maximums
for that interval will be displayed as shown in the following diagram.
2.
If the warning count is set to 2 or higher, Warning will appear on the screen
if the measurement result enters the warning range continuously that num-
ber of times or more.
End
Detailed conditions
Recording interval
Warning count
Display average
Display maximum
Display minimum
NG by warning
Graph line
:
:
:
:
:
:
:
[ 1]
[ 1]
ON
ON
ON
OFF
2dot
Specify an interval between 1 and 99,999 (1*) for recording
values for the graph, i.e., the number of measurements
before a value is recorded. (See note 1.)
Specify the number of times the measurement must fall in
the warning range before a warning is generated. (1 to 999
(1*)) (See note 2.)
Select whether or not to display the average for the number of
measurements set under recording interval. (ON*, OFF)
Select whether or not to display the maximum and minimum
for the number of measurements set under recording interval.
(ON*, OFF)
Select whether or not to set the judgement for this unit to NG
if a warning is generated. (ON, OFF*)
Specify the width of graph lines (1 dot, 2 dot*)
Lines are finer if set to 1 dot and processing time is faster
than if 2 dot is set.
Disp.200
400.000
350.000
450.000
Meas. :
226.000
Judge :
NG Warning
0.Scn 0
RUN
Maximum displayed in OK color.
Average displayed in NG color.
Minimum displayed in OK color.
The measurement value is updated for
each measurement, regardless of the
recording interval.
No warning display the first time.
Warning appears on the screen
when measurement result enters
warning range continuously for the
number of times set to warning
count or more.
Upper
judgement limit
Warning range
(upper limit)