6-2-(21)
Normal Serial Interface
Section 6-2
Output
Command executed correctly:
Password data Delimiter
OK Delimiter
Command not executed correctly:
ER Delimiter
Example
In this example, the password is set to AAAAAAA.
Input
PASSWORD Delimiter
Output
AAAAAAA Delimiter
OK Delimiter
6-2-2-16
RESET
Function
Resets the Controller.
Input
RESET Delimiter
Output
None
6-2-2-17
SCENE
Function 1
Reads the scene number of the scene being used.
Input
SCENE Delimiter
Output
Command executed correctly:
Scene number Delimiter
OK Delimiter
Command not executed correctly:
ER Delimiter
Example
In this example, scene 0 is being used.
Input
SCENE Delimiter
Output
0 Delimiter
OK Delimiter
Function 2
Switches the scene number.
Input
SCENE <scene number> Delimiter
Specify a scene number between 0 and 31.
Output
Command executed correctly:
OK Delimiter
Command not executed correctly:
ER Delimiter
Example
In this example, the scene is switched to scene 2.
Input
SCENE 2 Delimiter
Output
OK Delimiter