6-3-(12)
Host Link Serial Interface
Section 6-3
CHECK
Write Flags: Each time that data is output, the write flags are switched
between “0000" and “1111". The status of these bits can be monitored to see
when data has been written.
0040: Re-register Model
Registers the models again for all regions for the specified unit number. (When
the through display is being used, the models will be registered based on the
last image that was measured.)
Re-registers all region models for the relevant unit.
CHECK
Model re-registration is valid only if model position compensation, circle posi-
tion compensation, fine matching, pattern inspection, rotation positioning, or
ECM search unit numbers have been specified. Any other specified unit num-
bers will be ignored.
CHECK
The model is re-registered for the current Camera image. If the Camera image
or Switch cameras image processing items are set to 2 or more units, use the
Up and Down Keys to switch between each input image. This is only possible
when the image size is set to All.
0066: Data Save
Saves the current scene group data and system data that is being used. Sys-
tem data is saved to scene group 0 data, if scene group 0 is the current scene
group, system data is saved to flash memory. The scene group data is saved
to the Memory Card if the current scene group number is between 1 and 31.
0092: Reset
Resets the Controller.
1060: Set Unit Data
Sets the specified unit’s parameters.
The data codes are the same as the ones used for the UNITDATA command.
Write
Area
word
Bits
Contents
15 to 12
11 to 8
7 to 4
3 to 0
+0
Write
flags
0000
0000
0000
Write flag
+1
0000
0000
10
1
digit
10
0
digit
Scene group number
(00 to 31)
Read
Area
word
Bits
Contents
15 to 12
11 to 8
7 to 4
3 to 0
+0
0000
0000
0100
0000
Command code
+1
10
3
digit
10
2
digit
10
1
digit
10
0
digit
Unit number (0 to 9999)
Read
Area
word
Bits
Contents
15 to 12
11 to 8
7 to 4
3 to 0
+0
0000
0000
0110
0110
Command code
Read
Area
word
Bits
Contents
15 to 12
11 to 8
7 to 4
3 to 0
+0
0000
0000
1001
0010
Command code