2-22-(11)
Rotation Positioning
Section 2-22
CHECK
It is also possible to set the binary level so that measurement is performed
only for an intermediate density range.
Edge
The edge registration method can be used when the measurement object is
rectangular.
Draw 4 regions. One edge is detected from each region and that becomes the
reference position.
1.
Setting Edge Detection Conditions
Set the direction to search for the 4 edges and the density change as the
measurement conditions.
Region 2
Region 3
Line connecting edge points
found for regions 0 and 1.
Search coordinates (cross point of lines)
Cross point not registered as reference
position if outside the model region.
Region 1
Line connecting edge points
found for regions 2 and 3.
Region 0
Edge
Measurement conditions
Region0
Region1
Region2
Region3
End
End
Region0 direction
Region0 Color
Region1 direction
Region1 Color
Region2 direction
Region2 Color
Region3 direction
Region3 Color
:
:
:
:
:
:
:
:
Light
Light
Light
Light
Dark
Dark
Dark
Dark
Edge detection direction:
,
,
,
.
Density change:
Light
dark, dark
light.
Example: Finding this position in region 0.
Direction:
Color: Light
dark