2-1-(7)
Inputting Camera Images
Section 2-1
A frame and display cursor will appear where the model was found and the
screen for inputting physical coordinates will be displayed.
12. Input the coordinates for the model position (display cursor) and select
End.
CHECK
Correcting Mistakes
Press the SHIFT+ESC Keys. The previous sampling can be corrected and re-
executed.
The first sampling will be confirmed, and the second screen will be dis-
played.
13. Repeat steps 9 to 12 and perform sampling for at least two locations.
Adjust the sampling region so that only the target figure is enclosed.
Once sampling has been completed, a confirmation message will be dis-
played.
14. Select Execute.
The settings will be registered and the screen in (2.) will return.
Specifying
Points
This function is used to specify and set any point in pixel units.
If the coordinates of the specified position are input, the calibration data is
automatically calculated. Up to 3 points can be specified.
+
X : [ 0.000]
Y : [ 0.000]
End
Sampling
1time(s)
+
Sampling
2time(s)
Registering calibration
Parameters.
Cancel
Execute