6-2-(40)
Normal Serial Interface
Section 6-2
Note
The displacement direction settings are shown in the following table.
The following settings data is for box measurement.
Settings
data
90
Region 0
Box color
0: Black
1: White
91
Result coordinate
0: Center 1: Upper left 2: Lower left
3: Upper right 4: Lower right
92
Defined side of
q
0: All 1: Upper 2: Lower 3: Left 4: Right
93
Long side (1 to 512)
94
Short side (1 to 484)
95
Long side lower limit (1 to 200)
96
Long side upper limit (1 to 200)
97
Short side lower limit (1 to 200)
98
Short side upper limit (1 to 200)
99
Long side distance lower limit (1 to 200)
100
Long side distance upper limit (1 to 200)
101
Short side distance lower limit (1 to 200)
102
Short side distance upper limit (1 to 200)
103
Line parallelism (1 to 99)
The following settings data is for multiple cross point measurement.
104
Region 0
Sorting method
0: X ascending order
1: X descending order
2: Y ascending order
3: Y descending order
The following settings data is for all measurements.
Settings
data
105
Region 1
Search region upper left X (0 to 511)
106
Search region upper left Y (0 to 483)
107
Search region lower right X (0 to 511)
108
Search region lower right Y (0 to 483)
to
... (Same as for region 0)
153
Line parallelism (1 to 99)
154
Sorting method
0: X ascending order
1: X descending order
2: Y ascending order
3: Y descending order
Data
Details
No.
Displacement X
Displacement Y
Displacement
q
0
None
None
None
1
Displacement compen-
sation region 0
None
None
2
Displacement compen-
sation region 0
Displacement compen-
sation region 0
None
3
Displacement compen-
sation region 0
Displacement compen-
sation region 1
None
4
None
Displacement compen-
sation region 0
None