2-12-(11)
Detecting Binary Defects
Section 2-12
Binary Tracking Function
Set the binary tracking function when the variations in measurement object
color or other factors prevent correct measurement with stable binary levels. If
the binary tracking function is set to ON, the Controller will automatically adjust
the binary levels in line with the brightness of the input image.
STEP 3: Drawing Measurement Regions
When a measurement region is drawn, measurement is performed for the dis-
played image and the results are registered as the reference values (area and
center of gravity).
CHECK
Regions can be created by combining up to 3 different figures. Regions with
difficult shapes can be drawn and sections not to be measured can be left out
of the region by combining different figures.
1.
Select Region.
The Region Settings Screen will be displayed.
2.
Select New.
3.
Select the desired figure.
4.
Select the desired drawing mode (OR/NOT).
An arrow cursor will appear.
Region0(Gravity and area)
Binary
Measurement conditions
Region
Reference registration
Judgement conditions
Detailed conditions
Clear
Region
New
End
Box
Ellipse
Circle
Circumference
Polygon
O
R
N O T
Region
[0]
375.341
Up to three figures (0, 1, and 2)
can be drawn.