6-2-(103)
Normal Serial Interface
Section 6-2
Function 2
Sets the parameters for the unit set to the current scene.
Input
UNITDATA <unit No.> <data> <parameter>Delimiter
• Specify a unit number between 0 and 9,999.
• The data will depend on the processing item for the specified unit.
SeeAlso
Refer to
/LVWRI'DWDRQSDJH
.
Output
Command executed correctly:
OK Delimiter
Command not executed correctly:
ER Delimiter
Example
In this example, the model position upper left X coordinate for region 0 for pat-
tern inspection is set to 100.
Input
UNITDATA 5 516 100 Delimiter
Output
OK Delimiter
6-2-2-32
UNITDAT2
Function 1
Reads the character string for QUEST character verification.
Input
UNITDAT2 <unit No.> <data> Delimiter
• Specify a unit number between 0 and 9,999.
• For information on data, refer to
/LVWRI'DWDRQSDJH
.
Output
Command executed correctly:
Value
OK Delimiter
Command not executed correctly:
ER Delimiter
Example
This example shows how to read the inspection character string for QUEST
character verification.
Input
UNITDAT2 7 979 Delimiter
Output
AAA Delimiter
OK Delimiter
Function 2
Sets character string for QUEST character verification.
Input
UNITDAT2 <unit No.> <data> <character string> Delimiter
• Specify a unit number between 0 and 9,999.
• For information on data, refer to
/LVWRI'DWDRQSDJH
.
Output
Command executed correctly:
OK Delimiter
Command not executed correctly:
ER Delimiter