2-26-(3)
Label Data
Section 2-26
2-26-1
Selecting the Reference Unit Number
Select the unit number of the processing item to be referenced. The unit num-
bers for which the following processing items are set will be displayed as
selections.
• Labeling
• Fine matching (Select a unit for which label area is set as the defect
detection method.)
• EC Defect (Select a unit that is set for a labeling inspection region.)
CHECK
Do not allow units for the following processing items to come between the
label data unit and the unit that is being referenced.
1.
Select Label data.
The initial display for Label Data will be displayed.
2.
Select Label unit.
A screen to select the unit number will be displayed.
3.
Select the unit number of the “labeling” processing item from which to get
the date.
4.
Select End.
The settings will be registered and the screen in (1.) will return.
Processing item
Affect
Camera image
Calibration will not be properly performed for the measure-
ment results of the Label Data processing item.
Switch camera
Processing items for
position compensation
The Label Data processing item will not be able to get the
data from before scrolling.
0.Camera image
1.Labeling
2.Label data
3.
0.Scn 0=SET=
ENT:Set SFT+ESC:Edit
Label unit
Label No.
Judgement conditions
Label unit
End
Label unit
: 1