2-17-(4)
Edge Position
Section 2-17
2-17-2
Setting Measurement Regions
Up to 8 regions can be set.
STEP 1: Setting Edge Detection Conditions
Set the direction for edge detection and the density changes.
1.
Select Edge position.
The settings selections will be displayed.
1
2
3
4
5
(As required)
(As required)
Set edge
detection
conditions.
Draw mea-
surement
region.
Re-register
reference
value.
Set
judgement
conditions.
Change
detailed
conditions.
Measurement conditions
End
Direction
Color
:
→
: Light
→
Dark
Edge detection direction:
→
,
←
,
↑
,
↓
Density change: Light
→
Dark, Dark
→
Light
Example: To detect the following position
Direction:
→
Color: Light
→
Dark
0.Scn 0=SET=
ENT:Set SFT+ESC:Edit
0.Camera image
1.Edge position
2.
1.Edge position
Measurement image
Select region
Coordinate mode