6-1-(10)
Parallel Interface
Section 6-1
Continuous Measurement
CHECK
Set the output period so that the total output time is shorter than the measure-
ment interval. If the output cycle is longer than the measurement cycle, the
output will gradually fall behind as measurements are repeated.
Example: When 3 Expressions Are Set for DO data
Output Signals
The functions of the output signals are the same as they are when the STEP
signal is used as the measurement trigger. (Refer to the tables on the preced-
ing pages.)
Input Signals
CHECK
The ERR signal will turn ON if the input command was not received correctly.
BUSY
OR
DO
GATE
RUN
OFF
ON
OFF
ON
OFF
ON
OFF
ON
DI7
DI0 to 6
Enter Run Mode
Exit Run Mode
Measuring
Overall judgement
Data 0
Data 1
Data 2
Measuring
Gate ON
delay
Gate ON
time
Output period
The total output period = Output period
Number of data items to be output
Signal
Function
DI0 to DI4
OFF
DI5
OFF
DI6
OFF
DI7
DI7 is the execution trigger.
After DI0 to DI6 are set, allow at least 1 ms before turning ON DI7. The
BUSY signal will be ON while continuous measurement is being per-
formed.