Radio Production System

TYPE R 

INSTALLATION MANUAL

Summary of Contents for TYPE R

Page 1: ...calrec com Radio Production System TYPE R INSTALLATION MANUAL...

Page 2: ...ational usage Calrec Audio Ltd reserve the right to change specifications without notice E O E The established policy of Calrec Audio Ltd is to seek improvements to the design specifications and manuf...

Page 3: ...sk Stand 720 999002 44 Fader LSP on Desk Stand 720 999003 46 LSP In Desk Mounting 720 999004 47 SSP In Desk Mounting 720 999005 49 Fader Panel In Desk Mounting 720 999006 51 Fader Panel Linking 720 99...

Page 4: ...gement Settings 90 AoIP Network Examples 101 Designing an AoIP AES67 Network 102 Type R AoIP AES67 network examples 102 Recommended third party equipment 102 Redundancy 104 Switch Port Quantities 104...

Page 5: ...calrec com TYPE R INFORMATION...

Page 6: ...fic to this document please contact enquiries calrec com Whenever you contact Calrec Customer Support please have the following information to hand Name Company Email Address Full details of enquiry e...

Page 7: ...wrapping Calrec Audio Limited can supply anti static wrapping upon request This applies particularly to digital products due to the types of devices and very small geometries used in their fabrication...

Page 8: ...t we recommend using a soft anti static cloth lightly dampened with water if required Explanation of Warning Symbols Triangular warning symbols contain a black symbol on a yellow background surrounded...

Page 9: ...DSP are all self contained within the 2U Core unit which has two IEC connectors to provide PSU redundancy The core operates at 44 1 48 96 kHz and supports up to 3 Consoles A number of DSP packages ar...

Page 10: ...10 TYPE R Radio Production System...

Page 11: ...calrec com TYPE R START UP GUIDE...

Page 12: ...t are present with the correct serial numbers A print out of the packing list will have been provided alongside the shipping documentation The packing list is a document named with your sales order nu...

Page 13: ...lit and after approximately 30 seconds the OK LED will light solid green to indicate a good status The Recover Led should be lit Green or not lit Fan Fail PSU Fail LEDs should not be lit 4 Configure...

Page 14: ...neral Configuration page will be displayed 3 Set the system date time 4 You may also set new System and Core names here These names will be used by the system to identify and announce cores as well as...

Page 15: ...customer contact s CALREC ONLINE SHOP SOFTWARE UPGRADE LICENCE PAGE CORE CONFIGURE DSP LICENCES PAGE 1 To install a licence key open the Core Configure application and navigate to System DSP Licences...

Page 16: ...n the Add ancillary panel dialogue See below right Note Where there are multiple fader panels multiple Add ancillary panel buttons will be available This is to allow you to position the panel in the s...

Page 17: ...esources before you continue Cisco Switch Management Settings for Physical Surface Panels The Cisco SG350 switch used for Surface Panel Interfacing needs to have its Energy Detect Mode Short Reach and...

Page 18: ...in the 192 168 30 24 for Primary AoIP port and 192 168 31 24 Secondary AoIP port address ranges and can be adapted as required Artel Switch Management Settings for AoIP AES67 Networks The Artel ARG s...

Page 19: ...settings should boot into config mode automatically To enter config mode manually follow the instructions below Fader panels hold down the first 3 buttons on the bottom button row before powering dur...

Page 20: ...the core 2 If the Core has been configured with a surface layout that matches the connected panels the panels will be discovered by the core If the panels are running a different software version to t...

Page 21: ...le Chrome type 172 16 255 25 into the address bar and press enter to navigate to the Assist landing page 2 In the menu on the left hand side navigate to Shows snapshots then Shows in the sub menu 3 In...

Page 22: ...22 TYPE R Radio Production System Start Up Guide SURFACE PANEL CONFIGURATION WITH ASSIST PC CONNECT OPTIONS TO SETUP MANAGEMENT STUDIO A...

Page 23: ...panel 4 Repeat this process for each Soft Panel in your surface Please refer to the Type R Assist and Console Panel Operation manual for more information on Type R Soft Panel Layouts 11 CREATE LAYOUTS...

Page 24: ...al Audio interface boxes types available for the Type R which are show in outline below The AD6501 is a 4 AES In with SRC 4 AES Out 8 Mic Line In with 48v 8 Line out Combo I O box with 2 x 6 35mm 1 4...

Page 25: ...t Important Currently the IP addresses and subnet masks assigned to the core s Connect server are fixed It will be possible to edit these settings from software release v1 2 Until then all AoIP device...

Page 26: ...onnect the next IO device and repeat steps 3 4 5 Once all IO box core AoIP device network interfaces are known to be set with unique IP addresses they may all be connected to the same network All IO b...

Page 27: ...be tested for use as a single studio system CALREC CONNECT SHOWING THE TYPE R CORE AOIP PORTS READY FOR CREATING TRANSMIT AND RECEIVE STREAMS CALREC CONNECT SHOWING THE COMBO AOIP DEVICE PORTS READY...

Page 28: ...our surface panels and to record the serial number fader range and label details of each panel for later reference After configuring the surface panels you may want to attach labels to them A blank la...

Page 29: ...01 24 16 15th 25 00011001 172 17 101 25 16 16th 26 00011010 172 17 101 26 16 17th 27 00011011 172 17 101 27 16 18th 28 00011100 172 17 101 28 16 19th 29 00011101 172 17 101 29 16 20th 30 00011110 172...

Page 30: ...umber Primary interface IP Address Subnet mask Secondary interface IP Address Subnet mask 1 192 168 30 1 24 192 168 31 1 24 2 192 168 30 2 24 192 168 31 2 24 3 192 168 30 3 24 192 168 31 3 24 4 192 16...

Page 31: ...splaying and controlling the fader surface saving and loading snapshots and patching inputs and outputs to the channels and buses There are then various sections about parameter access including proce...

Page 32: ...32 TYPE R Radio Production System...

Page 33: ...calrec com TYPE R CONTROL SURFACE DIMENSIONS...

Page 34: ...duction System Control Surface Dimensions TOP VIEW SIDE VIEW IM6413 6 WAY FADER PANEL The following diagrams show the surface measurements of the IM6413 6 way Fader Panel in millimetres mm inches in S...

Page 35: ...35 FRONT VIEW IM6413 6 WAY FADER PANEL REAR VIEW IM6413 6 WAY FADER PANEL Note These panels can be fastened together to form larger console surfaces...

Page 36: ...n System Control Surface Dimensions TOP VIEW SIDE VIEW MU6411 LARGE SOFT PANEL The following diagrams show the surface measurements of the MU6411 Large Soft Panel in millimetres mm inches in FRONT VIE...

Page 37: ...37 BOTTOM VIEW MU6411 LARGE SOFT PANEL REAR VIEW MU6411 LARGE SOFT PANEL Note These panels can be fastened together to form larger console surfaces...

Page 38: ...System Control Surface Dimensions TOP VIEW SIDE VIEW MU6410 SMALL SOFT PANEL The following diagrams show the surface measurements of the MU6410 Small Soft Panel all in millimetres mm inches in FRONT V...

Page 39: ...39 BOTTOM VIEW MU6410 SMALL SOFT PANEL REAR VIEW MU6410 SMALL SOFT PANEL Note These panels are designed to be located wherever a simple control interface is required...

Page 40: ...40 TYPE R Radio Production System...

Page 41: ...calrec com TYPE R FIXING BRACKET ASSEMBLY INSTRUCTIONS...

Page 42: ...dge 17mm to desk surface without feet with feet 20 5mm Assembly Tools required not supplied 7mm adjustable spanner wrench open ended PZ2 screw driver bit Determine height and location required on surf...

Page 43: ...Wood screws not supplied Saw Follow instructions for 720 999006 Fader in desk mounting kit but Fader opening size will require extending to 418mm 16 45in x 247mm 9 7in Offer up fader panel through ope...

Page 44: ...fixing hole positions see Fig2 a bottom edge 15mm to desk surface without feet with feet 20mm b bottom edge 25mm to desk surface without feet with feet 30mm Stand Base With stick on feet supplied Wit...

Page 45: ...SSP with bracket Item 1 from base item 2 Fix base Item 2 to desk top with screws not provided using the 2 marked fixing holes as reference Re attach interface bracket Item 1 to base Item 2 with 3 x M...

Page 46: ...attach using 2 Screws item 6 with washers item 5 7 with plain washer towards bracket as shown in Fig 4 Loosely attach LSP bracket Item 1 to LSP with 4 screws Item 6 and washers item 5 6 Align with fi...

Page 47: ...mm FIG 2 LARGE SOFT PANEL IN DESK MOUNTING MODES A B FIG 1 LARGE SOFT PANEL IN DESK Flush mounting options a Fig 2 for desk thickness 9 20mm b Fig 2 for desk thickness 40 50mm c Fig 3 for desk thickne...

Page 48: ...in bracket Item 1 with LSP and attach stand using 4 x M4 screws Item 5 with washers Items 3 4 Note plain washer should be nearest bracket As shown Fig 5 Fitting to desk surface Cut hole in desk 247mm...

Page 49: ...G 2 SMALL SOFT PANEL IN DESK MOUNTING MODES A B FIG 1 SMALL SOFT PANEL IN DESK Flush mounting options a Fig 2 for desk thickness 10 20mm b Fig 2 for desk thickness 40 50mm c Fig 3 for desk thickness 0...

Page 50: ...washer should be nearest bracket As shown Fig 6 Set Panel ID as once fitted it may be difficult to do so and offer up the SSP through the hole in desk from the underside Fitting to desk surface Fix br...

Page 51: ...mm to 25mm 56mm 15 25mm FIG 2 FADER PANEL IN DESK MOUNTING MODE A FIG 1 FADER PANEL IN DESK Flush mounting options a Fig 2 for desk thickness 15 25mm b Fig 3 for desk thickness 0 25mm FIG 3 FADER PANE...

Page 52: ...ig 2 3 Align holes in bracket Item 1 with Fader Panel and attach stand using 4 x M4 screws Item 4 with washers Items 3 6 Note plain washer should be nearest bracket As shown Fig 5 Fitting to desk surf...

Page 53: ...uire extending to 418mm 16 45in x 247mm 9 7in Offer up fader panel through opening from underside Fix brackets 720 999006 item2 to underside of desk with 4 screws not supplied suitable for desk surfac...

Page 54: ...embly Instructions FADER PANEL LINKING 720 999007 Fader panel IM6413 to Fader Panel IM6413 Linking Option FIG 1 FADER PANEL TO FADER PANEL LINKING FIG 2 LINKING PANEL PROCEDURE 1st Panel 2nd Panel 1st...

Page 55: ...ake 1st Fader panel from left and turn fader panel over with front edge towards you Attach 2 brackets Item 1 to left hand side of fader panel Align holes in bracket Item 1 with Fader panel and attach...

Page 56: ...ctions LARGE SOFT PANEL LINKING 720 999008 Large Soft panel MU6411 to Large Soft Panel MU6411 Linking Option FIG 1 LARGE SOFT PANEL TO LARGE SOFT PANEL LINKING FIG 2 LINKING PANEL PROCEDURE 1st Panel...

Page 57: ...nels located as you require take 1st Fader panel from left and turn the panels over with top of the panels towards you Align holes in bracket Item 1 with Fader panel and attach using 4 x M4 screws Ite...

Page 58: ...58 TYPE R Radio Production System...

Page 59: ...calrec com TYPE R SYSTEM ELEMENTS...

Page 60: ...nectors which connect to the various surfaces via PoE switches Typically each of these connect to a separate PoE switch interfacing to a number of Fader LSP and SSP panels More than one connection is...

Page 61: ...faders has 4 large user definable buttons a dedicated 96x96 pixel TFT display for fader status information and at the top of each fader are 2 user buttons a rotary control with integrated push switch...

Page 62: ...or on the rear edge of the panel provides both power and data connections MU6410 Small Soft Panel SSP This panel shown bottom right consists of a smaller 1024x600 pixel touch sensitive TFT display for...

Page 63: ...the up on position represents a binary 1 Each switch binary bit equates to a decimal value starting at 1 for the least significant bit The remaining switches are double the value of their less signif...

Page 64: ...ne In with 48v and 16 Line out Analogue I O box with 6 GPI and 6 GPO interfaces The JD6503 is an 8 AES In with SRC and 8 AES Out AES I O Box with 6 GPI and 6 GPO interfaces In addition to the 2 x IEC...

Page 65: ...ample below shows two switches which offers a diversity of connections to the 24 fader Console In addition to the panels a PC is connected providing the Calrec Assist application for configuration and...

Page 66: ...TWORK CONFIGURATION AT A GLANCE The drawing below shows an overview of the factory default network configuration of each device in a Type R system Please refer to the Surface Panel Layout and AoIP Net...

Page 67: ...67...

Page 68: ...7 1 22 16 172 18 1 22 16 172 19 1 22 16 Configure 172 29 1 23 16 172 17 1 23 16 172 18 1 23 16 172 19 1 23 16 Router 172 29 1 24 16 Twin Controller 172 29 1 25 16 Rear Interface 1 2 1 2 1 2 1 2 5 6 Su...

Page 69: ...failure or a loss of AC power input will generate a system status error message The two PSU s employ load sharing If one PSU fails the other will automatically take over the full load with no loss of...

Page 70: ...70 TYPE R Radio Production System...

Page 71: ...calrec com TYPE R SYNC AUDIO GPIO CONNECTIONS...

Page 72: ...uire that all equipment connected to the audio console s digital inputs and outputs are locked to the same referenced sync source as the console to ensure clean audio It is of paramount importance tha...

Page 73: ...ne inputs Note that there are 8 x 48v indicator LEDs to show when phantom power is being applied to each input to this connector The pinout for analogue inputs 9 16 on the AD6502 Analogue I O Box is i...

Page 74: ...01 Combo I O Box and the AD6502 Analogue I O Box and conforms to the AES59 Tascam standard Analogue Audio Out RJ45 type Connector This connector is used for 2 x balanced Line outputs The pinout for an...

Page 75: ...or appears on the UR6500 Core Box AD6501 Combo I O Box and the JD6503 AES I O Box and conforms to the AES59 Tascam standard AES Audio In RJ45 type Connector This connector is used for 1 x AES input po...

Page 76: ...x and conforms to the AES59 Tascam standard AES Audio Out RJ45 type Connector This connector is used for 1 x AES output ports The pinout for AES output ports 2 3 4 is identical to the port 1 pinout Th...

Page 77: ...GPO connector GPI inputs Each GPI connector carries six GPI circuits based on a simple opto isolated design capable of interfacing with any DC signal between 5V and 24V Each input is designed to be a...

Page 78: ...6 on Pin 8 This connector appears on the UR6500 Core Box x 2 AD6501 Combo I O Box AD6502 Analogue I O Box and the JD6503 AES I O Box GPO RJ45 type Connector This connector is used for 6 x GP Outputs N...

Page 79: ...calrec com TYPE R CORE DSP PACK OPTIONS...

Page 80: ...nnel paths R20 Base 20 DSP channel paths 1 x Console 20 DSP channel paths 8 Aux buses 8 Group buses 3 Main buses R40 Option 40 DSP channel paths 1 1 x Console 40 DSP channel paths 16 Aux buses 8 Group...

Page 81: ...are 4 variants depending on which DSP packages have been made available from 20 to 120 DSP channels Mix buses will also vary depending on the DSP channel size with only the two larger DSP packs R80 an...

Page 82: ...Mix Minus Mix Paths 4 4 Conference Mix Paths 2 2 Total Mix Paths 32 32 32 Mix Paths Mix Paths mono equivalent Width Paths Note Main 1 PGM1 Paths Mono Stereo or 5 1 14 Pool of 14 Paths may be assigned...

Page 83: ...DSP Paths 42 42 84 Mix Paths mono equivalent Main 1 PGM1 Paths 14 14 28 Main 2 PGM2 Paths Main 3 REC Paths Group Paths Aux Paths 8 8 16 PFL Mix Paths 2 2 4 AFL Mix Paths 2 2 4 Mix Minus Mix Paths 4 4...

Page 84: ...hs 6 6 Mix Minus Mix Paths 4 4 Conference Mix Paths 2 2 Total Mix Paths 64 64 R80 Option 2 Console 1 Console 2 Totals 40 CH 40 CH DSP Paths mono equivalent Channel Paths 40 40 80 Aux Paths 16 16 32 Ma...

Page 85: ...otal Mix Paths 48 32 32 112 64 Mix Paths Mix Paths mono equivalent Width Paths Note Main 1 PGM1 Paths Mono Stereo or 5 1 30 Pool of 30 Paths may be assigned as Mono Stereo or 5 1 Main 2 PGM2 Paths Mon...

Page 86: ...oup Paths Aux Paths 16 16 PFL Mix Paths 6 6 AFL Mix Paths 6 6 Mix Minus Mix Paths 4 4 Conference Mix Paths 2 2 Total Mix Paths 64 64 R120 Option 2 Console 1 Console 2 Totals 60 CH 60 CH DSP Paths mono...

Page 87: ...ivalent Channel Paths 80 40 120 Aux Paths 16 16 32 Main Group Paths 30 22 52 Total DSP Paths 126 78 204 Mix Paths mono equivalent Main 1 PGM1 Paths 30 22 52 Main 2 PGM2 Paths Main 3 REC Paths Group Pa...

Page 88: ...32 24 8 3 32 20 20 20 32 24 8 Per Pack 96 60 60 60 96 72 24 1 64 44 44 44 64 48 16 2 32 20 20 20 32 24 8 Per Pack 96 64 64 64 96 72 24 1 48 32 32 32 48 24 12 2 24 16 16 16 24 24 6 3 24 16 16 16 24 24...

Page 89: ...calrec com TYPE R SURFACE PANEL LAYOUT EXAMPLES...

Page 90: ...h are not supplied with the switch 2 Cisco SG350 10 K9 10 port 8 2 switch Calrec 491 267 8 x 1Gbps RJ45 2 x combo RJ45 SFP 1Gbps slots that can accept 1Gbps interfaces Note that the use of the 2 x SFP...

Page 91: ...91 EXAMPLE 1 12 FADER SURFACE...

Page 92: ...92 TYPE R Radio Production System Surface Panel Layout Examples EXAMPLE 2 18 FADER SURFACE...

Page 93: ...93 EXAMPLE 3 24 FADER SURFACE...

Page 94: ...94 TYPE R Radio Production System Surface Panel Layout Examples EXAMPLE 4 TWO STUDIO INSTALLATION...

Page 95: ...95...

Page 96: ...96 TYPE R Radio Production System Surface Panel Layout Examples EXAMPLE 5 THREE STUDIO INSTALLATION...

Page 97: ...97...

Page 98: ...98 TYPE R Radio Production System Surface Panel Layout Examples EXAMPLE 5 THREE STUDIO INSTALLATION WITH REDUNDANT CORE...

Page 99: ...99...

Page 100: ...100 TYPE R Radio Production System Surface Panel Layout Examples EXAMPLE 6 SINGLE STUDIO INSTALLATION WITH REDUNDANT CORE...

Page 101: ...calrec com TYPE R AOIP NETWORK EXAMPLES...

Page 102: ...ber 491 268 4 All cabling shown is via RJ45 Cat5e shielded twisted pair STP cables Cisco and Artel Switch Management Settings for AoIP AES67 Networks Note Both the Cisco switch and the Artel ARG Quarr...

Page 103: ...erface card fitted to Core TypeR Core Pri CONNECT Server AoIP 1 CH 1 256 A B AoIP 2 CH 257 512 A B A B 3 Type R Core with Calrec Connect stream management server installed 2 AoIP AES67 Interface cards...

Page 104: ...s Type R Cores can be supplied without any AoIP Interfaces fitted in which case although the two pairs of AoIP connectors are fitted these will not be functional Optionally one or two AoIP Interfaces...

Page 105: ...dicated audio network there is still additional traffic Higher channel counts can be achieved but deterministic network conditions are required to successfully exceed the safe working recommendations...

Page 106: ...switches provide connections to end points and are interconnected by spine switches Each leaf needs a connection to each spine The following diagram shows the architecture of a Leaf and Spline network...

Page 107: ...NGLE CORE WITH LOCAL I O 2 AOIP I O BOXES ON A NON PTP SWITCH EXAMPLE 3 SINGLE CORE WITH LOCAL I O 2 AOIP I O BOXES ON 2 REDUNDANT PTP SWITCHES Note In this case a single switch is being used for both...

Page 108: ...E R Radio Production System AoIP Network Examples EXAMPLE 4 SINGLE CORE WITH LOCAL I O 4 AOIP BOXES ON 2 REDUNDANT PTP SWITCHES EXAMPLE 5 SINGLE CORE WITH LOCAL I O 10 AOIP BOXES ON 4 REDUNDANT PTP SW...

Page 109: ...109 EXAMPLE 6 6 STUDIOS SINGLE CORE WITH LOCAL I O 12 AOIP I O BOXES ON 8 REDUNDANT PTP SWITCHES Note The dotted Links may be added to provide cable redundancy between switches...

Page 110: ...110 TYPE R Radio Production System AoIP Network Examples EXAMPLE 7 6 STUDIOS MCR SINGLE CORES 2 AOIP CARDS CORE WITH LOCAL I O 20 AOIP I O BOXES ON 12 REDUNDANT SWITCHES...

Page 111: ...111...

Page 112: ...h keeps the Secondary Core in step with the Primary Core The link may be wired with a single cable or two for cable redundancy b The direct link between the A and B switches is to provide PTP sync Thi...

Page 113: ...will not be available on the Redundant Secondary Core For I O signals where redundancy is required we recommend the use of networked Type R I O Boxes Connection Notes The direct link between the Prima...

Page 114: ...I O 8 AOIP BOXES ON 8 REDUNDANT PTP SWITCHES I O Note In the event of a Redundant Secondary Core takeover any I O connected to the Primary Core local I O will not be available on the Redundant Second...

Page 115: ...direct link between the Primary and Secondary Type R Cores is via the Core Surface connections which keeps the Secondary Core in step with the Primary Core The link may be wired with a single cable or...

Page 116: ...WITH LOCAL I O 32 AOIP I O BOXES ON 12 REDUNDANT SWITCHES I O Note In the event of a Redundant Secondary Core takeover any I O connected to the Primary Core local I O will not be available on the Redu...

Page 117: ...direct link between the Primary and Secondary Type R Cores is via the Core Surface connections which keeps the Secondary Core in step with the Primary Core The link may be wired with a single cable or...

Page 118: ...S ON 12 REDUNDANT SWITCHES NOTE CONNECT SERVERS ARE INSTALLED ON PC S RATHER THAN CORES I O Note In the event of a Redundant Secondary Core takeover any I O connected to the Primary Core local I O wil...

Page 119: ...direct link between the Primary and Secondary Type R Cores is via the Core Surface connections which keeps the Secondary Core in step with the Primary Core The link may be wired with a single cable or...

Page 120: ...120 TYPE R Radio Production System AoIP Network Examples...

Page 121: ...calrec com TYPE R SOFTWARE UPDATER...

Page 122: ...connected PC type 172 16 255 40 into the address bar and press enter to navigate to the Software Updater landing page Note If Google Chrome is not installed navigate to https www google com chrome to...

Page 123: ...guide Once updated create a new show and perform a full system power cycle Ensure the Recover LED on the front of the is either solid green or off before you do this Once power cycled ensure the recov...

Page 124: ...on number in the file name 6 If a firmware version newer than the version installed on your system is available double click on it to download it to your PC 7 Navigate to the AoIP device web page agai...

Page 125: ...calrec com TYPE R SPECIFICATIONS...

Page 126: ...legs Monitor Inserts Dedicated Insert available to Console LS Studio1 LS and Misc LS Mix Minus Buses 2 Stereo Off Air Conference Bus 1 Stereo External Monitor Meter Inputs 48 VCA Groups Unlimited EQ...

Page 127: ...ide to side to form bigger surfaces as long as clearance is provided below the units to provide the panels with sufficient ventilation Operating Ambient Air Temperature 0 C 40 C UR6500 Type R Core 240...

Page 128: ...1U Rack is cooled by natural ventilation and does not require fan assistance having sufficient surface area to radiate heat adequately The side panels of the I O unit should be unobstructed with at le...

Page 129: ...t from Type R I O units depends on the supply voltage and loading Typically it is 0 55 times the RMS VA Volts x Amperes at 230V and 0 7 times the RMS VA at 115V Heat output figures are available for a...

Page 130: ...ne Inputs Distortion 1dBFS 1kHz Better than 0 005 86dB 20dBFS 1kHz Better than 0 003 90dB 40 dBFS 1kHz Better than 0 03 70dB Dynamic Range CCIR RMS 116dB Idle Channel Noise 116dBFS 88dBu Equivalent In...

Page 131: ...RATE PROVISIONAL FIGURES From To Via Samples 48kHz 96kHz AES3 inputs SRC off AES3 Outputs Port to port 18 0 376ms 0 188ms AES3 Outputs channel group and aux or main output 30 0 626ms 0 313ms Analogue...

Page 132: ...926 228 Iss 8 Calrec Audio Ltd Nutclough Mill Hebden Bridge West Yorkshire England UK HX7 8EZ Tel 44 0 1422 842159 Fax 44 0 1422 845244 Email Enquiries calrec com calrec com...