Parameters
(T) Multi-Function Input Terminal Parameters
FR-A800
5 - 429
●
When the RT (X9) signal is ON, the following second (third) functions are selected at the same time.
The function can be changed by switching the RT signal ON/OFF while the inverter is stopped. If
a signal is switched during operation, the operation method changes after the inverter stops,
(Pr. 450
≠
9999).
When the RT signal is OFF, the first function is selected and when it is ON, the second function is
selected.
Function
First function
Parameter number
Second function
Parameter number
Third function
Parameter number
Refer to
page
Torque boost
Pr. 0
Pr. 46
Pr. 112
Base frequency
Pr. 3
Pr. 47
Pr. 113
Acceleration time
Pr. 7
Pr. 44
Pr. 110
Deceleration time
Pr. 8
Pr. 44, Pr. 45
Pr. 110, Pr. 111
Pr. 9
Pr. 51
Pr. 600 to Pr. 604
Pr. 692 to Pr. 696
Motor permissible load
level
Pr. 607
Pr. 608
Stall prevention
Pr. 22
Pr. 48, Pr. 49
Pr. 114, Pr. 115
Pr. 71
Pr. 450
Motor constant
Pr. 80 to Pr. 84,
Pr. 89 to Pr. 94, Pr. 298,
Pr. 702, Pr. 706, Pr. 707,
Pr. 711, Pr. 712, Pr. 717,
Pr. 721, Pr. 724, Pr. 725,
Pr. 859
Pr. 453 to Pr. 457, Pr. 560,
Pr. 569, Pr. 458 to Pr. 462,
Pr. 738 to Pr. 747, Pr. 860
Offline auto tuning
Pr. 96
Pr. 463
Online auto tuning
Pr. 95
Pr. 574
PID control
Pr. 127 to Pr. 134
Pr. 753 to Pr. 758
PID Pre-charge
function
Pr. 760 to Pr. 764
Pr. 765 to Pr. 769
Brake sequence
Pr. 278 to Pr. 285, Pr. 639,
Pr. 640
Pr. 641 to Pr. 648, Pr. 650,
Pr. 651
Droop control
Pr. 286 to Pr. 288, Pr. 994,
Pr. 995
Pr. 679 to Pr. 683
Low-speed range
torque characteristics
Pr. 788
Pr. 747
Motor control method
Pr. 800
Pr. 451
Speed control gain
Pr. 820, Pr. 821
Pr. 830, Pr. 831
Analog input filter
Pr. 822, Pr. 826
Pr. 832, Pr. 836
Speed detection filter
Pr. 823
Pr. 833
Torque control gain
Pr. 824, Pr. 825
Pr. 834, Pr. 835
Torque detection filter
Pr. 827
Pr. 837
Tab. 5-169:
Functions, that can be set as second or third functions
NOTES
RT signal is assigned to the terminal RT in the initial status. Set "3" in any of Pr. 178 to Pr. 189 (input
terminal function selection) to assign the RT signal to another terminal.
When both the RT signal and X9 signal are ON, the X9 signal (third function) is prioritized.
Changing the terminal assignment using Pr. 178 to Pr. 189 (input terminal function selection) may
affect the other functions. Set parameters after confirming the function of each terminal.
Parameters referred to
Pr. 178 to Pr. 189
(input terminal function selection)
=>
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......