(A) Application parameters
Parameters
5 - 558
Setting the upper and lower limits of the PID manipulated amount (Pr. 1134, Pr. 1135)
●
Set the upper and lower limits of the PID manipulated amount.
●
The upper limit of the manipulated amount is the frequency obtained by adding the value
resulting from frequency conversion of Pr. 1134 to the main speed.
The lower limit of the manipulated amount is the frequency obtained by subtracting the value
resulting from frequency conversion of Pr. 1135 from the main speed.
I002710E
Fig. 5-278:
Upper and lower limits of the PID manipulated amount
Out
p
ut
fr
eque
nc
y
Upper limit of PID manipulated amount
Main speed
Lower limit of PID manipulated
amount
Output frequency considering upper/lower limit
of PID manipulated amount
Time
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......