Control method
Parameters
5 - 74
Initial value for the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.
Initial value for the FR-A820-03800(75K) or higher and FR-A840-02160(75K) and higher.
Setting Pr. 71 "Applied motor" = "333, 334, 8093, 8094, 9093, or 9094" does not change the Pr. 71
setting.
#
When a value other than "9999" is set, the set value is not changed.
,
200 r/min when Pr. 788 "Low speed range torque characteristic selection" = "0".
$
13.33 Hz when Pr. 788 "Low speed range torque characteristic selection" = "0".
%
110% for SLD, 120% for LD, 150% for ND, and 200% for HD
(Refer to Pr. 570 "Multiple rating setting" page 5-201.)
&
The Pr. 702 "Maximum motor frequency" is used as the maximum motor frequency. When Pr. 702 =
"9999 (initial value)", the Pr. 84 "Rated motor frequency" is used as the maximum motor frequency.
386
Frequency for maximum
input pulse
60 Hz
50 Hz
2000 r/min
Pr. 84
133.33 Hz
Pr. 84
1 r/min
0.01 Hz
505
Speed setting reference
60 Hz
50 Hz
133.33 Hz
Pr. 84
133.33 Hz
Pr. 84
0.01 Hz
557
Current average value
monitor signal output
reference current
Rated inverter
current
Rated motor
current
(Refer to
Pr. 859
Rated motor
current
(Refer to
Pr. 859
0.01 A
820
Speed control P gain 1
60%
30%
1%
821
Speed control integral
time 1
0.333 s
0.333 s
0.001 s
824
Torque control P gain 1
(current loop proportional
gain)
100%
100%
1%
825
Torque control integral time
1 (current loop integral
time)
5 ms
20 ms
0.1 ms
870
Speed detection hysteresis
0 Hz
8 r/min
0.5 Hz
1 r/min
0.01 Hz
885
Regeneration avoidance
compensation frequency
limit value
6 Hz
200 r/min
Pr. 84 × 10%
13.33 Hz
Pr. 84 × 10%
1 r/min
0.01 Hz
893
Energy saving monitor
reference (motor capacity)
Rated inverter
capacity
Motor capacity (Pr. 80)
0.01 kW
C14
(918)
Terminal 1 gain frequency
(speed)
60 Hz
50 Hz
2000 r/min
Pr. 84
133.33 Hz
Pr. 84
1 r/min
0.01 Hz
1121
Per-unit speed control
reference frequency
Maximum
motor
frequency
200 Hz
Maximum
motor
frequency
1 r/min
0.01 Hz
⎯
: Not changed
NOTE
If IPM parameter initialization is performed in rotations per minute (Pr. 998 = "3003, 8009, or
9009"), the parameters not listed in the table and the monitored items are also set and displayed
in rotations per minute.
Pr.
Name
Setting
Setting increments
Induction
motor
PM motor
(rotations per minute)
PM motor (frequency)
Pr. 998
0
(initial value)
3003
(MM-CF)
8009
9009
(other than
MM-CF)
3103
(MM-CF)
8109
9109
(other than
MM-CF)
3003,
8009,
9009
0, 3103,
8109,
9109
FM
CA
Tab. 5-27:
IPM parameter initialization list (2)
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......