(C) Motor constant parameters
Parameters
5 - 444
Setting
●
To perform tuning, set the following parameters about the motor.
Differs according to the voltage class. (200 V/400 V)
For the settings for the SF-V5RU refer to page 2-74.
According to the Pr. 71 setting, the range of the motor constant parameter setting values and units
can be changed. Set the Pr. 71 "Applied motor setting" according to the motor to be used and the
motor constant setting range. (For other setting values of Pr. 71, refer to page 5-434.)
First
motor Pr.
Second
motor Pr.
Name
Initial value
Description
80
453
Motor capacity
9999 (V/F control) Set the motor capacity (kW).
81
454
Number of motor
poles
9999 (V/F control) Set the number of motor poles (2 to 12).
800
451
Control method
selection
20
Set this parameter when using vector control or Real
sensorless vector control.
9
51
Electronic thermal O/L
relay
Rated inverter
current
Set the rated motor current (A).
83
456
Rated motor voltage
200 V/400 V
Set the rated motor voltage (V) printed on the
motor's rating plate.
84
457
Rated motor
frequency
9999
Set the rated motor frequency (Hz).
When the setting is "9999", the Pr. 3 "Base frequency"
setting is used.
71
450
Applied motor
0 (standard
motor)
Set this parameter according to the motor.
Three types of motor constant setting ranges, units
and tuning data can be stored according to settings.
96
463
Auto tuning setting/
status
0
Set "1" or "101".
1: Performs tuning without rotating the motor.
(Excitation noise occurs at this point.)
101: Performs tuning without rotating the motor.
The motor can rotate up to the speed near the rated
motor frequency.
Tab. 5-174:
Set the parameters before performing tuning
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......