(N) Operation via communication and its settings
Parameters
5 - 644
C31 (926)
42116
Terminal 6 bias (speed)
Read/
Write
Analog value (%) set to C31 (926)
43926
Terminal 6 bias (speed)
(terminal analog value)
Read
Analog value (%) of voltage applied to terminal 6
of the FR-A8AZ
C32 (927)
41927
Terminal 6 gain frequency (speed)
Read/
Write
C33 (927)
42117
Terminal 6 gain (speed)
Read/
Write
Analog value (%) set to C33 (927)
43927
Terminal 6 gain (speed)
(terminal analog value)
Read
Analog value (%) of voltage applied to terminal 6
of the FR-A8AZ
C34 (928)
41928
Terminal 6 bias command (torque)
Read/
Write
C35 (928)
42118
Terminal 6 bias (torque)
Read/
Write
Analog value (%) set to C35 (928)
43928
Terminal 6 bias (torque)
(terminal analog value)
Read
Analog value (%) of voltage applied to terminal 6
of the FR-A8AZ
C36 (929)
41929
Terminal 6 gain command (torque)
Read/
Write
C37 (929)
42119
Terminal 6 gain (torque)
Read/
Write
Analog value (%) set to C37 (929)
43929
Terminal 6 gain (torque)
(terminal analog value)
Read
Analog value (%) of voltage applied to terminal 6
of the FR-A8AZ
C8 (930)
41930
Current output bias signal
Read/
Write
C9 (930)
42120
Current output bias current
Read/
Write
Analog value (%) set to C9 (930)
C10 (931)
41931
Current output gain signal
Read/
Write
C11 (931)
42121
Current output gain current
Read/
Write
Analog value (%) set to C11 (931)
C38 (932)
41932
Terminal 4 bias command
(torque)
Read/
Write
C39 (932)
42122
Terminal 4 bias (torque)
Read/
Write
Analog value (%) set to C39 (932)
43932
Terminal 4 bias (torque)
(terminal analog value)
Read
Analog value (%) of current (voltage) applied to
terminal 4
C40 (933)
41933
Terminal 4 gain command
(torque)
Read/
Write
C41 (933)
42123
Terminal 4 gain (torque)
Read/
Write
Analog value (%) set to C41 (933)
43933
Terminal 4 gain (torque)
(terminal analog value)
Read
Analog value (%) of current (voltage) applied to
terminal 4
C42 (934)
41934
PID display bias coefficient
Read/
Write
C43 (934)
42124
PID display bias analog value
Read/
Write
Analog value (%) set to C43 (934)
43934
PID display bias analog value
(terminal analog value)
Read
Analog value (%) of current (voltage) applied to
terminal 4
C44 (935)
41935
PID display gain coefficient
Read/
Write
C45 (935)
42125
PID display gain analog value
Read/
Write
Analog value (%) set to C45 (935)
43935
PID display gain analog value
(terminal analog value)
Read
Analog value (%) of current (voltage) applied to
terminal 4
1000 to
1999
45000 to
45359
For details on parameter names,
refer to the parameter list
(page 5-2).
Read/
Write
The parameter +44000 is the register
number.
Pr.
Register Name
Read/
Write
Remarks
Tab. 5-296:
Parameters (2)
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......