Parameters
Position control under vector control and PM sensorless vector control
FR-A800
5 - 175
Cumulative pulse division scaling factor (Pr. 636, Pr. 637)
●
Set the division scaling factor on the cumulative pulse in Pr. 636 or Pr. 637.
●
Cumulative pulse count value calculation method
(Cumulative pulse count value) = (Cumulative pulse division scaling factor) x ((Cumulative pulse
overflow times) x 32768 + (Cumulative pulse monitor value))
Cumulative pulse count value: Number of pulses multiplied by 4
Cumulative pulse division scaling factor: Pr. 636 or Pr. 637
Cumulative pulse monitor value clear (Pr. 635)
●
The cumulative pulse monitor and the cumulative pulse overflow times can be cleared by X52
signal or X53 signal.
●
To input the X52 or X53 signal, set "52 (X52)" or "53 (X53)" in any of Pr. 178 to Pr. 184 (input terminal
function selection) to assign the function to a terminal.
●
Use Pr. 635 "Cumulative pulse clear signal selection" to select the clearing method for the
cumulative pulse monitor and the cumulative pulse overflow times.
Pr. 635
X52 signal
Cumulative pulse monitor clear
X53 signal
Cumulative pulse monitor clear
(control terminal option)
0
Cleared at the edge when the signal is switched to ON. Cleared at the edge when the signal is switched to ON.
1
Cleared while the signal is ON.
Cleared at the edge when the signal is switched to ON.
2
Cleared at the edge when the signal is switched to ON.
Cleared while the signal is ON.
3
Cleared while the signal is ON.
Cleared while the signal is ON.
Tab. 5-66:
Pr. 635 settings
I002855E
Fig. 5-70:
Clearing condition
Cumulative pulse
Cumulative pulse
overflow times
Cumulative pulse
Cumulative pulse
overflow times
Clear signal
(X52, X53)
Clear signal
(X52, X53)
Cleared at the ON edge
Cleared while the signal is ON
ON
ON
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......