Protective functions
Causes and corrective actions
FR-A800
6 - 9
6.5
Causes and corrective actions
6.5.1 Error
message
A message regarding operational troubles is displayed. Output is not shut off.
Operation panel
indication
HOLD
Name
Operation panel lock
Description
Operation lock is set. Operation other than STOP/RESET key is invalid. (Refer to page 5-198.)
Check point
⎯
Corrective action
Press MODE key for 2 s to release the lock.
Operation panel
indication
LOCD
Name
Password locked
Description
Password function is active. Display and setting of parameters are restricted.
Check point
⎯
Corrective action
Enter the password in Pr. 297
"
Password lock/unlock
"
to unlock the password function before
operating. (Refer to page 5-211.)
Operation panel
indication
Er1
Name
Parameter write error
Description
앫
Parameter setting was attempted while Pr. 77 "Parameter write selection" is set to disable
parameter write.
앫
Overlapping range has been set for the frequency jump.
앫
Overlapping range has been set for the adjustable 5 points V/F.
앫
The PU and inverter cannot make normal communication.
앫
IPM parameter initialization was attempted while Pr. 72 = "25".
Check point
앫
Check the Pr. 77 "Parameter write selection" setting. (Refer to page 5-203.)
앫
Check the settings of Pr. 31 to Pr. 36 (frequency jump). (Refer to page 5-312.)
앫
Check the settings of Pr. 100 to Pr. 109 (adjustable 5 points V/F). (Refer to page 5-660.)
앫
Check the connection of PU and the inverter.
앫
Check the Pr. 72 "PWM frequency selection" setting. A sine wave filter cannot be used under
PM sensorless vector control.
Operation panel
indication
Er2
Name
Write error during operation
Description
Parameter write was attempted while Pr. 77 = "0".
Check point
앫
Check that the inverter is stopped.
Corrective action
앫
After stopping the operation, make parameter setting.
앫
When setting Pr. 77 = "2", parameter write is enabled during operation.
(Refer to page 5-203.)
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......