Electro-magnetic interference (EMI) and leakage currents
Precautions for use of the inverter
3 - 10
How to enable or disable the filter
●
Before removing a front cover, check to make sure that the indication of the inverter operation
panel is OFF, wait for at least 10 minutes after the power supply has been switched OFF, and check
that there is no residual voltage using a tester or the like.
●
For FR-A820-00105(1.5K) or higher and FR-A840-00023(0.4K) or higher
When disconnecting the connector, push the fixing tab and pull the connector straight without
pulling the cable or forcibly pulling the connector with the tab fixed.
When installing the connector, also engage the fixing tab securely.
If it is difficult to disconnect the connector, use a pair of needle-nose pliers, etc.
●
For FR-A820-00077(0.75K) or lower
–
Remove the control circuit terminal block. (Refer to page 7-11.)
–
Connect the shorting wire to the corresponding terminal to enable or disable the filter.
Connect the wire to the terminal in the same way as general wiring of the control circuit
terminal block. (Refer to page 2-43.)
–
After switching, reinstall the control circuit terminal block as it was.
I001053E
Fig. 3-8:
Activating the built-in EMC filter
NOTES
Fit the connector or shorting wire to either ON or OFF position.
Enabling (turning ON) the EMC filter increases leakage current. (Refer to page 3-3.)
P
WARNING:
While power is ON or when the inverter is running, do not open the front cover. Otherwise you
may get an electric shock.
EMC filter
ON/OFF connector
(Side view)
Disengage connector fixing tab
With tab disengaged,
pull up connector straight.
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......