Parameters
(M) Monitor display and monitor output signal
FR-A800
5 - 371
Regenerative status output signal (Y32)
●
When the motor is in the regenerative status (motor is in the dynamic braking status) under vector
control, the Regenerative status output (Y32) signal turns ON. Once it turns ON, the signal is
retained for at least 100 ms.
●
The signal turns OFF during a stop or pre-excitation.
●
To use the Y32 signal, set "32 (positive logic) or 132 (negative logic)" in any of Pr. 190 to Pr. 196
(output terminal function selection) to assign the function to the output terminal.
Fault output signals (ALM, ALM2)
●
The Fault (ALM, ALM2) signals are output when the inverter protective function is activated.
●
The ALM2 signal stays ON during the reset period after the fault occurs.
●
To use the ALM2 signal, set "94 (positive logic) or 194 (negative logic)" in any of Pr. 190 to Pr. 196
(output terminal function selection) to assign the function to the output terminal.
●
The ALM signal is assigned to the A1B1C1 contacts in the initial status.
I002625E
Fig. 5-168:
Forward and reverse rotation of the motor
NOTES
Always OFF under V/F control, Advanced magnetic flux vector control, Real sensorless vector con-
trol, and PM sensorless vector control.
I001153E
Fig. 5-169:
Fault signals
NOTE
For the inverter fault details, refer to page 6-9.
Y32
Less than 100 ms
Regeneration
–
Driving
+
Signal is retained for 100 ms.
Time
ON
OFF
ON
Inverter alarm occurrence (trip)
Ou
tp
u
t
fr
equenc
y
ALM
Reset ON
Time
RES
ALM2
Reset processing
(about 1s)
ON
ON
ON
OFF
OFF
OFF
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......