Installation and wiring
Communication connectors and terminals
FR-A800
2 - 57
2.7
Communication connectors and terminals
2.7.1 PU
connector
Mounting the operation panel or parameter unit on the enclosure surface
Having an operation panel or a parameter unit on the enclosure surface is convenient. With a con-
nection cable, the operation panel or the parameter unit can be mounted to the enclosure surface
and connected to the inverter.
Use the option FR-CB2
첸
, or connectors and cables available on the market.
To mount the operation panel (FR-DU08, FR-LU08), the optional connector (FR-ADP) is required.
Securely insert one end of the connection cable until the stoppers are fixed.
Communication operation
Using the PU connector enables communication operation from a personal computer, etc. When the
PU connector is connected with a personal, FA or other computer by a communication cable, a user
program can run to monitor the inverter or read and write parameters.
Communication can be performed with the Mitsubishi inverter protocol (computer link operation).
For the details, refer to page 5-600.
I002382E_F
Fig. 2-41:
Connecting a parameter unit or the operation panel using a connection cable
NOTES
Refer to the following table when fabricating the cable on the user side. Keep the total cable
length within 20 m.
Commercially available products (as of November 2013)
U
P
D
W
F
F
T
S
Operation panel connection
connector
(FR-ADP) (option)
Operation panel
(FR-DU08)
Parameter unit connection cable
(FR-CB2
첸
)(option)
Parameter unit (FR-PU07)
(option)
Operation panel (FR-LU08)
(option)
Name
Model
Manufacturer
Communication cable
SGLPEV-T (Cat5e/300 m) 24AWG × 4P
Mitsubishi Cable Industries, Ltd.
RJ-45 connector
5-554720-3
Tyco Electronics
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......