Basic operation
Basic operation procedure (External operation)
FR-A800
4 - 23
쑶
Example
쑴
Operation example: Operate at 30 Hz.
Operation
Changing the operation mode
Set "3" in Pr. 79. [PU] and [EXT] indicators are lit. (For setting value change, refer to page 4-6.)
Setting the frequency
Turn
to until the target frequency, "
" (30.00 Hz), appears. The frequency flickers for about 5 s.
While the value is flickering, press
to enter the frequency. "
" and "
" flicker alternately.
After about 3 s of flickering, the indication goes back to "
" (monitor display).
(If
is not pressed, the indication of the value goes back to "
" (0.00 Hz) after about 5 s of flickering.
In that case, turn
again and set the frequency.)
Start
➔
acceleration
➔
constant speed
Turn ON the start switch (STF or STR). The frequency value on the indication increases in Pr. 7 "Acceleration time",
and "
" (30.00 Hz) appears. [FWD] indicator is lit during the forward rotation, and [REV] indicator is lit
during the reverse rotation.
(To change the set frequency, perform the operation in above step
. The previously set frequency appears.)
#
Deceleration
➔
stop
Turn OFF the start switch (STF or STR). The frequency value on the indication decreases in Pr. 8 "Deceleration
time", and the motor stops rotating with "
" (0.00 Hz) displayed.
Tab. 4-15:
Operate the inverter by using external signals
NOTES
When both the forward rotation switch (STF) and the reverse rotation switch (STR) are ON, the
motor cannot be started. If both are turned ON while the inverter is running, the inverter deceler-
ates to a stop.
Pr. 178 "STF terminal function selection" must be set to "60" (or Pr. 179 "STR terminal function
selection" must be set to "61"). (All are initial values.)
Setting Pr. 79 "Operation mode selection" = "3" also enables multi-speed operation.
If stopped using STOP/RESET key on the operation panel during the External operation, the
inverter enters the PU stop status.
("PS" appears on the operation panel.)
To reset the PU stop status, turn OFF the start switch (STF or STR), and then press PU/EXT key.
(Refer to page 5-194.)
Parameters referred to
Pr. 4 to Pr. 6
(multi-speed setting)
=>
Pr. 7
Acceleration time
=>
Pr. 8
Deceleration time
=>
Pr. 178
STF terminal function selection
=>
Pr. 179
STR terminal function selection
=>
Pr. 79
Operation mode selection
=>
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......