Causes and corrective actions
Protective functions
6 - 12
Operation panel
indication
rE6
Name
File error
Description
앫
The parameter copy file in the USB memory device cannot be recognized.
앫
An error has occurred in the file system during transfer of the PLC function data or writing to
RAM.
Check point
⎯
Corrective action
앫
Perform parameter copy again.(Refer to page 5-704.)
앫
Copy the PLC function project data again.(Refer to page 5-591.)
Operation panel
indication
rE7
Name
File quantity error
Description
앫
A parameter copy was attempted to the USB memory device in which the copy files from
001 to 099 had already been saved.
Check point
앫
Check if the number of copy files in the USB memory device has reached 99.
Corrective action
앫
Delete the copy file in the USB memory device and perform parameter copy again.(Refer to
page 5-704.)
Operation panel
indication
rE8
Name
No PLC function project file
Description
The specified PLC function project file does not exist in the USB memory device.
Check point
앫
Check that the file exists in the USB memory device.
앫
Check that the folder name and the file name in the USB memory device is correct.
Corrective action
The data in the USB memory device may be damaged.
Operation panel
indication
Err.
Name
Error
Description
앫
The RES signal is turned ON.
앫
The operation panel and inverter cannot make normal communication (contact faults of the
connector).
앫
This error may occur when the voltage at the input side of the inverter drops.
앫
When using a separate power source for the control circuit power (R1/L11, S1/L21) from the
main circuit power (R/L1, S/L2, T/L3), this error may appear at turning ON of the main circuit.
It is not a fault.
Corrective action
앫
Turn OFF the RES signal.
앫
Check the connection between the operation panel and the inverter.
앫
Check the voltage on the input side of the inverter.
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......