Protective functions
Causes and corrective actions
FR-A800
6 - 33
Operation panel
indication
E.OD
FR-LU-08
Position fault
Name
Excessive position fault
Description
The inverter trips when the difference between the position command and position feedback
exceeds Pr. 427 "Excessive level error" under position control.
Check point
앫
Check that the position detecting encoder mounting orientation matches the parameter.
앫
Check that the load is not large.
앫
Check that the Pr. 427, Pr. 369 (851) "Number of encoder pulses" settings are correct.
Corrective action
앫
Check the parameters.
앫
Reduce the load.
앫
Set Pr. 427, Pr. 369 correctly.
Operation panel
indication
E.MB1 to E.MB7
to
FR-LU-08
E.MB1 Fault to
E.MB7 Fault
Name
Brake sequence fault
Description
The inverter trips when a sequence error occurs during use of the brake sequence function
(Pr. 278 to Pr. 285). This protective function is not available in the initial status. (The brake
sequence function is invalid.) (For the details of fault record, refer to page 5-484.)
Check point
Find the cause of the fault occurrence.
Corrective action
Check the set parameters and perform wiring properly.
Operation panel
indication
E.EP
FR-LU-08
Encoder signal loss
Name
Encoder phase fault
Description
The inverter trips when the rotation command of the inverter differs from the actual motor
rotation direction detected from the encoder during offline auto tuning. This protective function
is not available in the initial status.
Check point
앫
Check for mis-wiring of the encoder cable.
앫
Check if the Pr. 359 852)"Encoder rotation direction" setting is incorrect.
Corrective action
앫
Perform connection and wiring securely.
앫
Change the Pr. 359 (852) setting.
Operation panel
indication
E.MP FR-LU-08
—
Name
Magnetic pole position unknown
Description
The inverter trips when the rotation command of the inverter differs from the actual motor
rotation direction detected from the encoder during offline auto tuning. This protective function
is not available in the initial status.
Check point
앫
Check for mis-wiring of the encoder cable.
앫
Check if the Pr. 359 "Encoder rotation direction" setting is incorrect.
Corrective action
앫
Perform connection and wiring securely.
앫
Change the Pr. 359 setting.
Vector
Vector
Vector
Vector
Vector
Vector
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......