(D) Operation command and frequency command
Parameters
5 - 278
Operation at fault
Selectable with Pr. 75 "Reset selection/disconnected PU detection/PU stop selection"
Selectable with Pr. 122 "PU communication check time interval", Pr. 336 "RS-485 communication
check time interval", and Pr. 548 "USB communication check time interval"
Follows the communication option
#
In the PU JOG operation mode, operation always stops when the PU is disconnected. The operation
of PU disconnection (E.PUE) follows the Pr. 75 "Reset selection/disconnected PU detection/PU stop
selection" setting.
,
When Pr. 550 "NET mode operation command source selection" = "1" (RS-485 terminals enabled),
or Pr. 550 "NET mode operation command source selection" = "9999" with no communication
option connected.
$
When Pr. 550 "NET mode operation command source selection" = "0" (communication option
enabled), or Pr. 550 "NET mode operation command source selection" = "9999" with communica-
tion option connected.
Fault record
Conditions
(Pr. 551 setting)
Operation in each operation mode at error occurrences
PU
operation
External
operation
External/PU
combined
operation
mode 1
(Pr. 79 =3)
External/PU
combined
operation
mode 2
(Pr. 79 =4)
NET
operation
(when RS-485
terminals are
used)
NET operation
(when
communication
option is used)
Inverter fault
⎯
Stop
PU connector
disconnection
2 (PU connector)
9999 (automatic
recognition)
Other than 2
Communication
error at PU
connector
2 (PU connector)
Stop/continued
Continued
Stop/
continued
Continued
Other than 2
Continued
Communication
error at RS-485
terminals
1 (RS-485
terminals)
Stop/continued
Continued
Stop/
continued
Continued
Other than 1
Continued
Continued
Communication
error at USB
connector
3 (USB connector)
9999 (automatic
recognition)
Stop/continued
Continued
Other than 3
Continued
Communication
error at
communication
option
⎯
Continued
Stop/continued
Tab. 5-110:
Operation at fault
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......