(T) Multi-Function Input Terminal Parameters
Parameters
5 - 398
Example
쑴
When Pr. 73 = "5"
By the terminal 1 (main speed) and terminal 2 (auxiliary) input, the setting frequency is set as shown
in the figure below.
쑶
NOTES
To use terminal 4, the AU signal needs to be turned ON.
To make compensation input for the multi-speed operation or remote setting, set Pr. 28 "Multi-
speed input compensation selection" = "1" (with compensation) (initial value "0").
After changing the Pr. 73 setting, check the voltage/current input switch setting. Incorrect setting
may cause a fault, failure or malfunction. (For the settings, refer to page 5-389.)
Parameters referred to
Pr. 28
Multi-speed input compensation selection
=>
Pr. 73
Analog input selection
=>
75
50
37,5
25
12,5
0
0
2,5
5
Terminal 1 input voltage [V]
Terminal 2:
5 V DC input (150 %)
Se
t f
re
q
u
e
n
c
y
[
Hz]
Terminal 2:
2.5 V DC input (100 %)
Terminal 2:
0 V DC input (50 %)
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......